Some of the pictures in this manual are a bit irritating. I had to dissassemble the unit and some of the screws have different threads, which is not mentioned in this manual. Also some of the drawings of the boards look different than the actual boards.
After all, the manual was very useful. I was able to recalibrate the capstan drive and it is working fine again.
 ;
This manual is very good. 303 pages scanned in a very high resolution. My camera has bad, leaking capacitors which all of the V5000 models are suffering from these days.
There is a huge part list with all capacitors, transistors etc. in this manual which helped me a lot. Otherwise I would not have been able to buy replacement parts.
The dissassembly guide is very enormous and detailed. Unlike on the Panasonic MS1 manual I downloaded here it actually looks like the real parts look. And the screws are labeled correctly, so you shouldn't have any left after the repair. ;)
 ;
has all the schematics you could need,and very well laid out format also has all part numbers along with an exploded view which is helpful
 ;
Very nice to have! Now it is no problem to understand how it is put together.
Helps me a lot.
 ;
good scans, all is clear. all pages in order. recommended
SECTION 4 MECHANICAL ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened swab: playback head pinch roller rubber belt capstan idlers 2. Demagnetize the playback head with a head demagnetizer. 3. Do not use a magnetized screwdriver for the adjustments. 4. After the adjustments, apply suitable locking compound to the parts adjusted. 5. The adjustments should be performed with the power supply voltage unless otherwise noted. � Torque Measurement
Mode Forward Forward Back Tension Reverse Reverse Back Tension FF, REW CQ-102C CQ-102RC CA-102RC CQ-201B Torqu Meter CQ-102C Meter Reading 30 - 65 g�cm (0.42 - 0.90 oz�inch) 0.5 - 4.5 g�cm (0.01 - 0.06 oz�inch) 30 - 65 g�cm (0.42 - 0.90 oz�inch) 0.5 - 4.5 g�cm (0.01 - 0.06 oz�inch) 60 - 200 g�cm (0.83 - 2.78 oz�inch)
SECTION 5 ELECTRICAL ADJUSTMENTS
TEST MODE This set have the test mode function. In the test mode, FM Auto Scan/Stop Level and AM (MW) Auto Scan/Stop Level adjustments can be performed easier than it in ordinary procedure. <Set the Test Mode> 1. Set the �power select� switch (S801) is �A� position. 2. Turn ON the regulated power supply. (All LEDs on the set lights up, and the clock is displayed.) Note: Press the [OFF] button, if the clock is not displayed. 3. Push the preset [4] button. 4. Push the preset [5] button. 5. Press the preset [1] button for more than two seconds. 6. Then the display indicates all lights, the test mode is set. <Release the Test mode> 1. Push the [OFF] button. 2. Return the �power select� switch (S801) to initially set position. See the adjustment location from on page 17 for the adjustment.
TAPE DECK SECTION
Tape Speed Adjustment Setting:
Meter Reading more than 90 g (more than 3.18 oz) more than 90 g (more than 3.18 oz)
0 dB=0.775 V
� Tape Tension Measurement
Mode Forward Reverse Torqu Meter CQ-403A CQ-403R
speed checker or frequency counter test tape WS-48A (3 kHz, 0 dB) 4�
set speaker out terminal
�
+
Procedure: 1. Put the set into the FWD PB mode. 2. Adjust adjustment resistor for inside capstan motor so that the reading on the speed checker or frequency counter becomes in specification. Specification: Constant speed
Speed checker �1.5 to +2.5% Frequency counter 2,955 to 3,075 Hz
Adjustment Location: See page 17.