Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
XR-A660, XR-A330
Recording Adjustment
(1) Bias Oscillation Frequency Adjustment
Step Mode Input Signal/ Test Tape Load the STD-632 test tape and set the recording mode. Adjusting Points Deck II DECK I    L2801 (AF Assy) Measurement Points    Between A point in Fig.7 and GND. Adjustment Value Oscillation frequency to be 105.0kHz ± 2kHz. Remarks If the REC/STOP button for four seconds while the power is in STAND BY mode, the frequency will decrease 2 to 3 kHz.
1
REC
(2) Recording Bias Adjustment
� Since this adjustment affects recording bias, prevent distortion from increasing due to underbias.
Step Mode Input Signal/Test Tape Input a 315Hz signal to the AUX terminal and set the input selector to AUX. Adjusting Points Deck II DECK I Deck II DECK I    Input signal level    VR2801(Lch) VR2802(Rch) Measurement Points TAPE TEST POINT (L, Rch) (AF Assy) TAPE TEST POINT (L, Rch) (AF Assy) Adjustment Value Remarks
1
REC
� 23.7dBV
2
Load the STD-632 test tape and REC � record/playback the 315Hz and PLAY 10kHz signals. (see the Note below)
Repeat adjustment until playback level of the 10kHz signal is within 0 ± 0.5dB from that of the 315Hz signal.
Note : Set the 10kHz input signal level to the same value as the 315Hz input signal level of step 1.
(3) Recording Level Adjustment
Step Mode Input Signal/Test Tape Input a 315Hz signal to the AUX terminal and set the input selector to AUX. Adjusting Points Deck II Input signal level DECK I Deck II DECK I    VR2301(Lch) VR2302(Rch) Measurement Points TAPE TEST POINT (L, Rch) (AF Assy) TAPE TEST POINT (L, Rch) (AF Assy) Adjustment Value Remarks
1
REC
�
7.7dBV
2
Load the STD-632 test tape and REC � record/playback the 315Hz PLAY signal.
Repeat recording, playback and adjustment until playback level of the 315Hz signal becomes � 7.7dBV.
(4) ALC Operation Check
Step 1 2 REC/ PAUSE Mode Input Signal/Test Tape Input a 315Hz signal to the AUX terminal and set the input selector to AUX. Adjusting Points Input signal level Set to a level +10dB adove the input level at step1. Measurement Points TAPE TEST POINT (L, Rch) (AF Assy) Adjustment Value � 8.2dBV Confirm that the reading is � 2.2 ± 2.5dBV. Remarks
56
|
|
|
> |
|