Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Complete service manual in very good scanning quality with all schematic and PWB graphics as well as assembly & maintenance instructions. A slight drawback is that the rastering of the PWB graphics sometimes makes it a bit difficult to follow fine traces, but no showstopper.
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site. Thank you very much
 ;
Service manual in good quality, it was very helpful to me. Perfect service, I am very satisfied.
Jochen Kelm
 ;
Exellent manual ,it was in great condition,and got all the info i expected,5 stars!!
 ;
I searched the Internet exhaustively for this manual and Owner-Manuals was the least expensive...but provided an excellent reproduction within 4 hours. Very satisified.
XR-C5300X/C5305/C5600X
SECTION 5 MECHANICAL ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened swab: playback head pinch roller rubber belt capstan idlers 2. Demagnetize the playback head with a head demagnetizer. 3. Do not use a magnetized screwdriver for the adjustments. 4. After the adjustments, apply suitable locking compound to the parts adjusted. 5. The adjustments should be performed with the power supply voltage unless otherwise noted. � Torque Measurement
Mode Forward Forward Back Tension Reverse Reverse Back Tension FF, REW CQ-102RC Torque Meter CQ-102C Meter Reading 2.95 � 6.37 N�m 30 � 65 g�cm (0.42 � 0.90 oz�inch) 0.05 � 0.44 N�m 0.5 � 4.5 g�cm (0.01 � 0.06 oz�inch) 2.95 � 6.37 N�m 30 � 65 g�cm (0.42 � 0.90 oz�inch) 0.05 � 0.44 N�m 0.5 � 4.5 g�cm (0.01 - 0.06 oz�inch) 5.89 � 19.61 N�m 60 � 200 g�cm (0.83 � 2.78 oz�inch)
SECTION 6 ELECTRICAL ADJUSTMENTS
6-1. TEST MODE <Set the Test Mode> 1. Set the �OFF� mode. 2. Push the preset [4] button. 3. Push the preset [5] button. 4. Press the preset [1] button for more than two seconds. 5. Then the display indicates all lights, the test mode is set. <Release the Test mode> 1. Push the [OFF] button. Adjustment Location:
� SET UPPER VIEW �
Tape Speed Adjustment
TAPE DECK SECTION
Tape Speed Adjustment Setting:
0 dB=0.775 V
CQ-102C
speed checker or frequency counter test tape WS-48A (3 kHz, 0 dB) set 10 k�
CQ-102RC
�
+
AUDIO OUT jack (J331)
CQ-201B
Procedure: 1. Put the set into the FWD PB mode. 2. Adjust adjustment resistor for inside capstan motor so that the reading on the speed checker or frequency counter becomes in specification. Specification: Constant speed
Speed checker �1.5 to +2.5% Frequency counter 2,955 to 3,075 Hz
� Tape Tension Measurement
Mode Forward Tension Meter CQ-403A Meter Reading more than 0.88 N more than 90 g (more than 3.18 oz) more than 0.88 N more than 90 g (more than 3.18 oz)
Reverse
CQ-403R
TUNER SECTION
0 dB=1 µV
The tuner section has no adjustment.
17