AM (MW) Auto Scan/Stop Level Adjustment Make this adjustment after �FM Auto Scan/Stop Level Adjustment�. Setting: [SOURCE] button: MW
30 � 15 pF
65 pF
AM RF signal generator AM dummy antenna (50 �)
set
Carrier frequency : 999 kHz 30% amplitude modulation by 1 kHz signal Output level : 33 dB (44.7 µV)
antenna jack (J1)
Procedure: 1. Set to the test mode. (See page 15.) 2. Push the [SOURCE] button and set to FM. 3. Push the [MODE] button and set to MW. Display
MW
999 @
INTRO
4. Adjust with the volume RV1 on TU1 so that the �MW� indication turns to �MW0� indication on the display window. But, in case of already indicated �MW0�, turn the RV1 so that put out light �0� indication and adjustment. Display
999
Adjustment Location: See page 19.