Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The AKAI 1720 model reel to reel tape recorder described in this Manual is quite an old unit - circa late 1960's. As a consequence, the description of the mechanical details - and adjustments thereof - is quite critical. The manual does this quite well. The schematics are also well presented and have detailed PCB overlays. Probably the only negative is that some half-tone detail has been lost from the original manual as it has been scanned in simple B&W.
 ;
Perfect source for service manuals: fast and professional transaction; high quality, perfect readable and largely scaleable PDF; complete schemes, diagrams and spare part list. Tnx a lot, cu again!!!!
 ;
I got your link from a friend and I must say that I am really satisfied with your service. Specially this B&O manual I didn't find anywhere on the web... but you could deliver it :-) . You deliver very fast and the copy is of good quality. So your webpage is bookmarked. Thanks
 ;
This was the Sony CCU-500A Service manual I was looking for.
The price was reasonable.
The permission to download was quck.
I will use Owner-Manual.com for all my manual needs.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
SECTION 3 MECHANICAL ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened swab: playback head pinch roller rubber belt capstan idler 2. Demagnetize the playback head with a head demagnetizer. 3. Do not use a magnetized screwdriver for the adjustments. 4. The adjustments should be performed with the power supply voltage (14.4 V) unless otherwise noted. Note: With this set, it is not necessary to apply suitable locking compound to the parts after the azimuth adjustment. � Torque Measurement
Mode Forward Forward Back Tension Reverse Reverse Back Tension FF, REW CQ-102RC Torque Meter CQ-102C Meter Reading 2.46 � 5.39 mN�m (25 � 55 g�cm) (0.35 � 0.76 oz�inch) 0.15 � 0.39 mN�m (1.5 � 4 g�cm) (0.02 � 0.06 oz�inch) 2.46 � 5.39 mN�m (25 � 55 g�cm) (0.35 � 0.76 oz�inch) 0.15� 0.39 mN�m (1.5 � 4 g�cm) (0.02 � 0.06 oz�inch) 4.91 � 14.70 mN�m (50 � 150 g�cm) (0.69 � 2.08 oz�inch)
XR-CA300/L200 SECTION 4 ELECTRICAL ADJUSTMENTS
TEST MODE This set have the test mode function. In the test mode, FM RDS SMeter, FM Auto Seek/Stop Level and MW Auto Seek/Stop Level adjustments can be performed easier than it in ordinary procedure. <Set the Test Mode> 1. Turn ON the regulated power supply. (All LEDs on the set lights up, and the clock is displayed.) Note: Press the [OFF] button, if the clock is not displayed. 2. Push the [4] button. 3. Push the [5] button. 4. Press the [1] button for more than two seconds. 5. Then the display indicates all lights, the test mode is set. <Release the Test mode> 1. Push the
[OFF] button.
CQ-102C
CQ-102RC
CQ-201B
� Tape Tension Measurement
Mode Forward Reverse Tension Meter CQ-403A CQ-403R Meter Reading more than 5.89 mN�m (more than 60 g) (more than 2.12 oz)
13
|
|
 |
> |
|