Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is the ONLY copy of this manual I could find for a realistic price. Even Panasonic could not provide me with one.
The PDF is a very good copy and it helped me diagnose and find the fault with the unit I have.
 ;
Very complete and well reading drawings. Documentation is essential for successful repairs.Good documentation, with all that is necessary. This manual was what I was waiting with all the information necessary for the repairing I need it for. You must buy it if you want to do repairs or simply understand how it works.
 ;
Excellent service manual includes everything is need to repair this radio-caseete, how to disassemble, wiring diagram, all , waiting time until the download was only a few hours. I'm going to buy service manuals from here, are cheap and very good.Thank you.
 ;
Good service manual,i saved from scrapping this deck,is now fully functional.Thanks.
 ;
Found this to be the manual included with the original packinging, was helpfull but did not give any detailed repair instructions.
ELECTRICAL ADJUSTMENT-2/9 (LH, C MODEL)
DECK ADJUSTMENT 1. TAPE SPEED ADJUSTMENT
Requirements � Measuring equipments : wow-flutter meter (frequency counter ) Test Tape : TTA-100 (3KHz) Test point : HP OUT Adjustment point : Tape speed adjustment point (motor) 1) Connect HP OUT to the Wow - flutter meter. 2) Insert the test tape (TTA-100), play back center of the tape and adjust the motor until it becomes 3,000Hz±30Hz.
WOW&FLUTTER METER Hz INPUT HP OUT %
2. WOW - FLUTTER CHECK
Requirements Test tape : TTA-100 (3KHz) Test point : HP OUT 1) Connect the HP OUT to the Wow - flutter meter. 2) Set the indicator to JIS and the mode to W RMS (WTD) of the Wow - flitter meter. 3) Play back thee center of the test tape (TTA-100) and check that it is below 0.35%.
HP OUT WOW&FLUTTER METER Hz INPUT %
3. HEAD AZIMUTH ADJUSTMENT
Requirements � Measuring equipment : Oscilloscope Test Tape : TTA-330 (8KHz) Test point : HP OUT Adjustment point : Head azimuth screw
Lch OSCILLOSCOPE
OUTPUT CH1 CH2
1) Connect the HP OUT to the oscilloscope of CH1 and CH2. 2) Set the V mode of the oscilloscope to ADD. 3) Insert the test tape (TTA-330) , play back the center of the tape and adjustment the head azimuth screw until the waveform of the oscilloscope has reached the maximum when playing back at 10KHz. 4) After the adjustment, bond lock (1600B) the screw.
Rch
4. REC. BIAS FREQUENCY ADJUSTMENT
Requirement � Measuring equipment : frequency counter Test point : TP9 1) Connect the TP9 to the frequency counter. 2) Set the recording condition to the main unit. 3) Adjust the L301 until it becomes 85KHz±5KHz.
TP9 GND FREQUENCY COUNTER Hz
-22-
|
|
 |
> |
|