you are doing great job guys.....my father ask me to find out the schematics of Sony KV25R1D to sort out the problem ..(he was electrical technician, and excperianced with TV and simillar stuff). finally he found the cause and change all necessary parts....now he has got working old dog..and is very happy!!... thank you all.. NB..he also saved the repair cost.
 ;
Perfect. Received my manual within 24 hours. Clear scan of the manual I needed. No problem.
 ;
Item as described, very well detailed manual with complete schematics. I've received the download information shortly after payment, very good support.
 ;
Really good and well scanned. File is complete the full service manual for 5$
3.JITTER CHECK 1) While oscilloscope is kept connected in the same test point as in step2. RF WAVEFORM CHECK, connect the output terminal of an oscilloscope to the input terminal of the jitter meter. 2) 3) 4) Set the VOLT range selector of oscilloscope to 500mV range or below. Play back 2nd track of TCD-782.
RF SW OUTPUT INPUT ns OSCILLOSCOPE JITTER METER
Check that jitter meter indicates 28.0ns or less.
Vref
4. PLAY ABILITY CHECK 1) Play back the 3rd , 8th and 13th track of ATD-001. Check that the noise does not occur sound skipping does not occur.
5.LASER CURRENT CHECK *Do not perform this measurement unless the laser is suspected to be defective. 1) 2) 3) Connect digital multi-meter across the resistor R402(10Ω). Play back the TCD-782 and check the DC voltage value on the digital multi-meter. Calculate the laser current (Iop) by dividing the DC voltage across R402 by the resistor value (R402= 10Ω). Check that the laser current (Iop) is 60mA or less.
R402 R402 DIGITAL MULTIMETER V
-33-
|
|
 |
> |
|