|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Manual found fast and good quality, very helpfull service
 ;
8-17-12 Been using the sight for about 6 months. Fast Downloads and top quality
Manuels !
 ;
Everything was great, the manual, the response time, the simplicity of the order, and the
Price. The only thing that I could possible say on a negative note would be that the manual I ordered was more for a service tech. There were a lot of schematic diagrams that didn't help me solve the problem. However I would order again and recommend the web sight to others.
 ;
I'd been looking for this manual for awhile. Exactly what I needed - and at an excellant price. Thanks!
 ;
very complete. acceptable resolution. details are a little unclear. is a manual note 8.
< DECK SECTION >
1. Tape Speed Adjustment Settings : � Test tape : TTA�100 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : SFR1 Method : Play back (FWD) the test tape and adjust SFR1 so that the frequency counter reads 3000Hz ± 5Hz and ± 45Hz (REV) with respect to forward speed. 2. Head Azimuth Adjustment Settings : � Test tape : TTA�300 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : Head azimuth adjustment screw Method : Play back (FWD) the 10kHz signal of the test tape and adjust screw so that the output becomes maximum. Next, perform on REV play mode. 3. PB Frequency Response Check Settings : � Test tape : TTA�300 � Test point :TP8 (Lch), TP9 (Rch) Method : Play back the 315Hz and 10kHz signals of the test tape and check that the output ratio of the 10kHz signal with respect to that of the 315Hz signal is 0dB ± 3dB. 4. PB Sensitivity Adjustment Settings : � Test tape : TTA�200 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : SFR303 (Lch) SFR304 (Rch) Method : Play back the test tape and adjust SFRs so that the output level of the test points becomes 245mV ± 10mV. 5. REC/PB Frequency Response Adjustment Settings : � Test tape : TTA�602 � Test point : TP8 (Lch), TP9 (Rch) � Input signal : 1kHz / 10kHz (LINE IN) � Adjustment location : SFR351 (Lch) SFR352 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP8, TP9 becomes 0dB (17mV). Record and play back the 1kHz and 10kHz signals and adjust SFRs so that the output of the 10kHz signals becomes 0dB ± 0.5dB with respect to that of the 1kHz signal. 6. REC/PB Sensitivity Adjustment Settings : � Test tape : TTA�602 � Test point : TP8 (Lch), TP9 (Rch) � Input signal : 1kHz (LINE IN) � Adjustment location : SFR305 (Lch) SFR306 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at TP8, TP9 becomes 0dB (170mV). Record and play back the 1kHz signals and adjust SFRs so that the output becomes 0dB ± 0.5dB.
< FRONT SECTION >
7. µ-CON OSC Adjustment Settings : � Test point : TP1 (K-SCAN) and GND � Adjustment location : L201 Method : Insert AC plug with pressing of TUNER and DISPLAY key. Adjust L201 so that the frequency across the test point is 194.898Hz ± 0.194Hz.
< CD SECTION >
8. Focus Gain Adjustment Settings : � Test disc : TCD-782 � Test point : TP2 (FE), TP3 (VREF) � Adjustment location : SFR130 Method : Play back the test disc (TCD-782, Track No.2) and adjust SFR130 so that the voltage between the test point (FE, VREF) becomes approx. 0mV.
� 40 �
|
|
 |
> |
|