Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is the second Manual I have ordered from owner-manuals, I give it five stars because it is exactly what I expected given the age of the equipment. So the contents look a bit aged and the pictures a bit grainy, it fulfills my needs and I am glad I can still get hold of them.
 ;
thank u so much for this manual that was so cheap that i thought it was a scam but i gambled anyway because it was too good of a deal to pass up and behold,the manual has everything and details of everything even the screws and im still amazed and very happy with my manual .so take my word and jump on it before they realize how cheap they selling thier manuals..thank you so much for taking time to read my thoughts
 ;
I do not have very much to say.
The price is quite covenient, delivery was better as promised (about 12 ours, against the specified 24 hours if I remember well), and the quality of the PDF is more than acceptable.
The Service Manual of Sansui R30 itself is also satisfactory: good graphic for schematics and layouts, simple and well structured.
Giovanni Bianchi
 ;
Happy to find finally a schematic for this amplifier. The schematic is of good quality, the pcb layout is useless: all is black. Never the less, it is very easy to find the components on the board using the schematics.
 ;
Hard to find manual was ready the next day. Scans were very legible (including schematics). All the essential parts of the service manual were present (adjustment procedure, schematics, and parts list). It would have been nice if the rest of the manual was included (disassembly procedure, theory of operation, etc.).
< DECK SECTION >
1. Tape Speed Adjustment Settings : � Test tape : TTA�100 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : SFR1 Method : Play back (FWD) the test tape and adjust SFR1 so that the frequency counter reads 3000Hz ± 5Hz and ± 45Hz (REV) with respect to forward speed. 2. Head Azimuth Adjustment Settings : � Test tape : TTA�300 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : Head azimuth adjustment screw Method : Play back (FWD) the 10kHz signal of the test tape and adjust screw so that the output becomes maximum. Next, perform on REV play mode. 3. PB Frequency Response Check Settings : � Test tape : TTA�300 � Test point :TP8 (Lch), TP9 (Rch) Method : Play back the 315Hz and 10kHz signals of the test tape and check that the output ratio of the 10kHz signal with respect to that of the 315Hz signal is 0dB ± 3dB. 4. PB Sensitivity Adjustment Settings : � Test tape : TTA�200 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : SFR303 (Lch) SFR304 (Rch) Method : Play back the test tape and adjust SFRs so that the output level of the test points becomes 245mV ± 10mV. 5. REC/PB Frequency Response Adjustment Settings : � Test tape : TTA�602 � Test point : TP8 (Lch), TP9 (Rch) � Input signal : 1kHz / 10kHz (LINE IN) � Adjustment location : SFR351 (Lch) SFR352 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP8, TP9 becomes 0dB (17mV). Record and play back the 1kHz and 10kHz signals and adjust SFRs so that the output of the 10kHz signals becomes 0dB ± 0.5dB with respect to that of the 1kHz signal. 6. REC/PB Sensitivity Adjustment Settings : � Test tape : TTA�602 � Test point : TP8 (Lch), TP9 (Rch) � Input signal : 1kHz (LINE IN) � Adjustment location : SFR305 (Lch) SFR306 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at TP8, TP9 becomes 0dB (170mV). Record and play back the 1kHz signals and adjust SFRs so that the output becomes 0dB ± 0.5dB.
< FRONT SECTION >
7. µ-CON OSC Adjustment Settings : � Test point : TP1 (K-SCAN) and GND � Adjustment location : L201 Method : Insert AC plug with pressing of TUNER and DISPLAY key. Adjust L201 so that the frequency across the test point is 194.898Hz ± 0.194Hz.
< CD SECTION >
8. Focus Gain Adjustment Settings : � Test disc : TCD-782 � Test point : TP2 (FE), TP3 (VREF) � Adjustment location : SFR130 Method : Play back the test disc (TCD-782, Track No.2) and adjust SFR130 so that the voltage between the test point (FE, VREF) becomes approx. 0mV.