Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very good service and quick service, very good quality of service manual!
 ;
Great tape deck manual!
I'm very positively surprised, because it is a very long manual, lot of pages, drawings, diagrams, description of how to make the alignment and adjustment procedures.
It is as good as the old "Naka" manuals from the 1970's - if somebody have seen them, they know what I mean by that.
I recommend to buy this very much !
 ;
I am a vintage hifi collector. No way to fix that device without the appropriate service manual...thanks to your site I got it and every thing is easier now. I got the manual right after ordering: fast cheap accurate ... thank you
 ;
Wonderful job clear. Qick fantastic. These people are really good. If even a problem arise they are wonderful assisting you. These scheme is so net despite this is a very old TV. Thank you for everything!!!!!!!!
 ;
Detailed schematic diagram, manual for professionals
< DECK SECTION >
1. Tape Speed Adjustment Settings : � Test tape : TTA�100 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : SFR1 Method : Play back (FWD) the test tape and adjust SFR1 so that the frequency counter reads 3000Hz ± 5Hz and ± 45Hz (REV) with respect to forward speed. 2. Head Azimuth Adjustment Settings : � Test tape : TTA�300 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : Head azimuth adjustment screw Method : Play back (FWD) the 10kHz signal of the test tape and adjust screw so that the output becomes maximum. Next, perform on REV play mode. 3. PB Frequency Response Check Settings : � Test tape : TTA�300 � Test point :TP8 (Lch), TP9 (Rch) Method : Play back the 315Hz and 10kHz signals of the test tape and check that the output ratio of the 10kHz signal with respect to that of the 315Hz signal is 0dB ± 3dB. 4. PB Sensitivity Adjustment Settings : � Test tape : TTA�200 � Test point : TP8 (Lch), TP9 (Rch) � Adjustment location : SFR303 (Lch) SFR304 (Rch) Method : Play back the test tape and adjust SFRs so that the output level of the test points becomes 245mV ± 10mV. 5. REC/PB Frequency Response Adjustment Settings : � Test tape : TTA�602 � Test point : TP8 (Lch), TP9 (Rch) � Input signal : 1kHz / 10kHz (LINE IN) � Adjustment location : SFR351 (Lch) SFR352 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP8, TP9 becomes 0dB (17mV). Record and play back the 1kHz and 10kHz signals and adjust SFRs so that the output of the 10kHz signals becomes 0dB ± 0.5dB with respect to that of the 1kHz signal. 6. REC/PB Sensitivity Adjustment Settings : � Test tape : TTA�602 � Test point : TP8 (Lch), TP9 (Rch) � Input signal : 1kHz (LINE IN) � Adjustment location : SFR305 (Lch) SFR306 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at TP8, TP9 becomes 0dB (170mV). Record and play back the 1kHz signals and adjust SFRs so that the output becomes 0dB ± 0.5dB.
< FRONT SECTION >
7. µ-CON OSC Adjustment Settings : � Test point : TP1 (K-SCAN) and GND � Adjustment location : L201 Method : Insert AC plug with pressing of TUNER and DISPLAY key. Adjust L201 so that the frequency across the test point is 194.898Hz ± 0.194Hz.
< CD SECTION >
8. Focus Gain Adjustment Settings : � Test disc : TCD-782 � Test point : TP2 (FE), TP3 (VREF) � Adjustment location : SFR130 Method : Play back the test disc (TCD-782, Track No.2) and adjust SFR130 so that the voltage between the test point (FE, VREF) becomes approx. 0mV.