Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
 ;
I was very pleased with the service provided and was surprised at how good the quality was of the manual. I thought it may be a third generation copy or so, but it is as good as the websites that charge 3 times this much. I repair some electronics for family and friends without charge, so this is perfect for me. Thank you very much.
 ;
The service was great and the document was also great. Highly recommend!!!!
If anyone has a users manual... Please email me. need one. $ [email protected]
 ;
I needed a service manual as the display on my oscilloscope was very dim. I thought I'd give owner-manuals.com a try, as they advertised a huge number of manuals. Sure enough they had one listed. I bought it hoping it would be useful... actually, I bought it hoping it would be readable! I've had manuals from online sources in the past, and been very disappointed. Not this time! An excellent manual, complete, and very readable. Using it I fixed my 'scope, and as such the manual was an investment that paid off manyfold. Do I have any complaints? One very minor one - The circuit diagrams could have been scanned at a higher resolution, as some of the details were a little difficult to make out - not impossible, just not as easy as my old eyes would like! Overall, I'm very satisfied with my manual, and I will certainly be using this company again. Well done.
 ;
I Have looked for this manual for quiet a while now, I have finally found it here. I believe this is the only place they have them in a very nice scan, pages are very clear to read, some of the pages are a bit tilted but overall it is great to have this manual available for purchase. Thanks
SECTION 1 ELECTRICAL ADJUSTMENTS
TUNER UNIT SECTION
� Use the following equipment for the electrical adjustment. Equipment 1 Monitor TV (XVM-6100, etc.) 2 Spectrum analyzer 3 TV signal generator 4 Digital voltmeter 5 Oscilloscope 6 Audio analyzer 7 DC power supply 8 Frequency counter Equipment Connections Connect the test equipment as shown in the figure below (unless otherwise instructed) and perform the adjustment.
DC power supply
TRAP Adjustment Procedure: 1. With the Power off, input the output of TG to TP30 (with DC cut by a capacitor (0.01 µF)). 2. Connect a spectrum analyzer to TP31 (with DC cut by a capacitor (0.01 µF)). 3. Adjust T1 so that the waveform peak is 40.9 MHz ± 50 Hz. 4. Adjust T2 so that the waveform peak is 31.9 MHz ± 50 Hz. 5. After this adjustment, open TP30 and TP31. (Disconnect the spectrum analyzer.)
T1= 40.9 MHz T2= 31.9 MHz
TV SG
ANT IN set
RF out
POWER (CN4)
VCO Adjustment Procedure: 1. No connection to ANT IN. (no signal state) 2. Connect a resistor (10 k�) between TP33 and +9 V (TP35). 3. Connect a spectrum analyzer to TP34 (with DC cut by a capacitor (0.01 µF)). 4. Adjust T3 so that the waveform peak is 38.9 MHz ± 1 kHz. 5. After this adjustment, open TP34. (Disconnect the spectrum analyzer.)
Setup during Adjustment Use the video signal obtained from the TV signal generator as the alignment signal, and check that this signal is within video output signal standards.
white (approx. 100%)
0.7 V 0.3 V 0.3 V red horizontal sync. signal burst signal (flat)
38.9 MHz
AGC Adjustment Procedure: 1. Set the TV SYSTEM switch to 1. 2. Input a color bar signal of E8ch (196.25 MHz) and 66 dBµV (75 � OPEN). 3. Connect the digital voltmeter to TP42. 4. Adjust VR1 so that reading on the digital voltmeter is 6.0 ± 0.1 V. AFT Adjustment Procedure: 1. Input a color bar signal of E8ch (196.25 MHz) and 74 dBµV (75 � OPEN). 2. Connect the oscilloscope to TP102. 3. Adjust T3 untill the waveform on the oscilloscope is 2.5 Vp-p.
Color bar signal from TV signal generator
Connection points: Refer to page 4. Adjustment points: Refer to page 4.
2.5 Vp-p 0V
Note: Small peaks (dips) coming out from the top of the waveform are unacceptable.
�2�
|
|
 |
> |
|