7.1.7 METHOD FOR DIAGNOSING DEGRADATION OF THE LDs ON THE PICKUP ASSY
Case when this diagnosis is required : When playback of any disc, including a test disc (DVD: GGV1025, CD: STD-905), won't play or doesn't play
A
How to diagnose
In the case mentioned above, degradation of the laser diodes (LDs) mounted on the 05SD Pickup Assy is suspected. Measure the voltage between the two ends of one of the resistors mentioned below.
No playback of a DVD :
B
Measure the voltage between the both ends of R322 or R325 on the DVDM Assy. If the voltage is 0.4 V or higher, the 650-nm LD is degraded.
No playback of a CD :
Measure the voltage between the both ends of R321 or R326 on the DVDM Assy. If the voltage is 0.4 V or higher, the 780-nm LD is degraded.
If the measurements show degradation of an LD, replace the 05SD Pickup Assy.
05SD PICKUP ASSY
C
CN101
B
DVDM ASSY
D
R325 R326
E
R321 R322
Front side
SIDE A
F
76
1 2
XV-DV333
3 4
|
|
 |
> |
|