There are currently no product reviews.
 ;
The manual arrived very quickly and had all the information I needed - Very satisfied with this seller. - Thanks -
 ;
Good quality, the manual help me to repair the echo/reverb section
 ;
A good service manual with lots of info and a very fair price
 ;
Great value, good scan, just as expected, everything that you need.
 ;
Good scan, great price, but almost the same with the SV260 service manual.
5
6
7
8
7.1.7 METHOD FOR DIAGNOSING DEGRADATION OF THE LDs ON THE PICKUP ASSY
Case when this diagnosis is required : When playback of any disc, including a test disc (DVD: GGV1025, CD: STD-905), won't play or doesn't play
A
How to diagnose
In the case mentioned above, degradation of the laser diodes (LDs) mounted on the 05SD Pickup Assy is suspected. Measure the voltage between the two ends of one of the resistors mentioned below.
No playback of a DVD :
Measure the voltage between the both ends of R322 or R325 on the DVDM Assy. If the voltage is 0.4 V or higher, the 650-nm LD is degraded. If the measurements show degradation of an LD, replace the 05SD Pickup Assy.
B
No playback of a CD :
Measure the voltage between the both ends of R321 or R326 on the DVDM Assy. If the voltage is 0.4 V or higher, the 780-nm LD is degraded.
PICKUP ASSY
C
CN101
B
DVD MAIN ASSY
D
Front side
SIDE A
E
F
XV-DV232
5 6 7 8
65
|