Complete service and operation manual. All schematics are there, all circuit boards AND add-on boards. Including exploded views ,component names and specifications. Also electrical and mechanical adjustment procedures are in this manual. This manual also covers the more advanced BR-S811E unit. Scan quality is fair and usable.
 ;
High quality scan of original Service Manual. Everything´s fine!
 ;
Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
 ;
The Service Manual received was helpful. The electronic information is exactly what I needed.
I recomend all of my friends about this technical page.
 ;
High quality scan of service manual. I am satisfied!
XV-HTD1
Trouble Shooting
Condition Condition Trouble Point
Tray does not open. (Nothing works) POWER OFF Key � "OFF" indication does not disappear 0 (OPEN) key � "OPEN" indication does not disappear 3 (PLAY) key � It becomes indication of "OPEN" from "NO DISC", and stop by the condition. (When a disc is not put in the Tray.)
Loading Motor is damage, disconnection or contact defectiveness.
1
Tray does not open. (Hear the clatter continuation sound.) It becomes the state that flashed indication of " 1 2 3 4 5
".
Contact defectiveness of Flexible Cable (7P) or the connector comes off, etc.. Tray Open/Close Position SW (S21) is damage or contact defectiveness, etc..
2 3
Tray opens it in POWER ON freely, and stay by the state.
Contact defectiveness of Flexible Cable (8P) or the connector comes off, etc..
4
Rotary Tray does not stop at the home position. (May stop on the way of rotation suddenly.)
Tray Position Detect Sensor (PC22) is damage or contact defectiveness, etc..
5
"CHANGE" indication does not change in POWER ON, and Rotary Tray does not move. (In this case only opening and closing of Tray are possible.)
Motor for Rotary Tray Drive is damage, disconnection or contact defectiveness.
6
Hear the clatter sound in clamp of the disc.
A gear of Planet Base deviates.
7 8
Rotation of Rotary Tray does not stop in POWER ON. In this case indication more than two which seems to be " 1 2 3 4 5 " lights, and abnormal indication appears.
Slit part of bottom of the Rotary Tray is damaged.
When Rotary Tray turns, hear the rattle and large sound.
Damage of Worm Gear or grease is insufficient.
9
Playback even if indicates it with "NO DISC". Take time till playbacks.
Disc Detect Sensor (PC21) is damage or contact defectiveness, etc..
10