Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
;
muy buen manual completo de buena calidad de impresion preciso y detallado , muy útil para la reparación.
;
The service manual is a good quality scan of the Panasonic NV-850, which is electrically identical to the Philips VR 6920, but mecanically just nearly.
XV-IS22DVD
FL
39
Description of Error
Causes if with a DVD
SGC could not converge during detects the peak
Causes if with a CD
Operation of the Unit
Open Stop
SGC converge timeout 41 Spindle timeout
The unit did not enter Stop mode within 10 seconds of issuance of a Stop command. The spindle could not converge into within ± 12% of the target FG rotation speed within 10 seconds after spindle kick. The first time after startup (the first time after disc distinction), it doesn't become the number of the target rotation within five seconds. The first time after startup, detects the abnormal rotation number of high-speed continuously 3 loops. DVD: 5 to 9 mS , CD: 40 to 60 mS After the second times after startup, it doesn't become the number of the target rotation within five seconds. Detects the abnormal high-speed or low-speed rotations. DVD: 5 to 9 mS , CD: 40 to 60 mS
48
Spindle FG transition timeout
Stops. (FG timeout)
Spindle PLL 49 transition timeout
Stops. ("73" is displayed during starting process.) Stops. ("73" is displayed during starting process.) Stop
4A Spindle lock timeout Spindle could not lock more than 1.5 seconds before start the AFB. 51 Auto sequence timeout of peak ABUSY did not return within 1 second after the DDTCT (peak detection) command was sent. ABUSY did not return within 30 mS after the FJMPD (Focus jump 1 to 0) command was sent. ABUSY did not return within 30 mS after the FJMPU (Focus jump 0 to 1) command was sent.
Auto sequence 52 timeout of focus jump down 53 54 Auto sequence timeout of focus
Stop
Stop Stop Stop
Auto sequence ABUSY did not return within 50 mS after the GSUMON timeout of play AGC (play-AGC-measuring) command was sent. ABUSY did not return within 2 seconds after the DJSRT (disc-sensing) command was sent. ABUSY did not return within 1 second after the TBLOFS (Internal ATB after the completion of external ATB) command was sent. ABUSY did not return within 500 mS after the TSON (tracking servo ON) command was sent. ABUSY did not return within 200 mS after the TBL (external ATB) command was sent. ABUSY did not return within 2 seconds after the FGN (focus gain adjustment) command was sent. ABUSY did not return within 2 seconds after TGN (tracking gain adjustment) command was sent. ABUSY did not return within 1 second after the CMDAVE (offset adjustment) command was sent. ABUSY did not return within 200 mS after the ADJMIR (modulation factor measurement) command was sent. ABUSY did not return within 2 seconds after the AFB (auto focus bias) command was sent. A command could not be sent because ABUSY was low. ABUSY did not return within 200 mS after TLV command was sent. Pause mode could not be restored within three retries after it had been released. An ID could not be read for 1 second or more. No frame could be read for 3 seconds or more. An ID could not be read within 1 second after the AFB adjustment had been finished.
Auto sequence 55 timeout of disc-typesensing Auto sequence 56 timeout of ATB2 Auto sequence 57 timeout of tracking servo ON Auto sequence 58 timeout of ATB1 Auto sequence 59 timeout of focus gain adjustment Auto sequence 5A timeout of tracking gain adjustment Auto sequence 5B timeout of offset adjustment Auto sequence 5C timeout of modulation factor measurement Auto sequence 5D timeout of auto focus bias Auto sequence 5F already busy 62 Pause retry error 71 ID can not read during tracing
Stop
Stop Stop Stop
Stop
Stop
Stop
Stop
Stop Continues operation Stop Stop
72 Subcode check failure during playback 73 ID can not read at the startup
Opens (ID readout failure)
74
|
|
|
> |
|