ELECTRICAL CONNECTION
The oven is designed to be connected to 240V - 50Hz electricity supply. The oven has an easily accessible terminal block which is marked as follows: "L" Live Terminal "N" Neutral Terminal Earth block. Connect the brown insulated wire to the terminal marked "L". Connect the blue insulated wire to the terminal marked "N". Connect the green and yellow insulated wire to the terminal marked . Tighten the cable clamps ensuring that there is no strain on the mains terminal. Replace the cover and tighten securing screws. Important After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature. Before the appliance is connected check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed. The manufacturers disclaim any responsibility should these safety instructions not be carried out. This appliance meets the requirements laid down in EEC Directive No. 89/336 relating to the suppression of radio and TV interferences.
THIS APPLIANCE MUST BE EARTHED
The cable used to connect he oven to the electrical supply should have the characteristics indicated in the table. If you require a direct connection to the electric network (mains), it is necessary that you install an omnipole switch between the appliance and the mains, with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required lead in compliance with the current rules. This switch must be easily accessible to the user on completion of the installation and must not break the yellow and green earth cable at any point. In order to connect the oven it is necessary to remove the plate at the back of the oven to reach the terminal
For UK use only
Models Upper oven rating Lower oven rating Cable cross section mm2 and type of the cable Fuse
ZBD 903
3580 W
2825 W
6 mm2 Type 6242Y
30 A.
For Europe use
Models Upper oven rating Lower oven rating Cable cross section mm 2 and type of the cable Fuse