Text excerpt from page 6 (click to view)
Adaptation to different types of gas
Replacement of injectors
� � � Remove the pan supports. Remove the burner's caps and crowns. With a socket spanner 7 unscrew and remove the injectors (Fig. 7), and replace them with the ones required for the type of gas in use (see table on the next page). � With a socket spanner 7 unscrew and remove the injectors (Fig. 7), and replace them with the ones required for the type of gas in use (see table 2): � Reassemble the parts, following the same procedure backwards. � Replace the rating label (placed near the gas supply pipe) with the relevant one for the new type of gas supply. You can find this label in the package of the injectors supplied with the appliance. Should the feeding gas pressure be different or variable compared with the required pressure, an appropriate pressure adjuster (for non-LPG) must be fitted on the gas supply pipe, in compliance with the rules in force.
Fig. 7
FO 0392
Adjustment of minimum level
To adjust the minimum level of the burners, proceed as follows:
Fig. 8
� � � �
Light the burner. Turn the knob on the minimum position. Remove the knob. With a thin screwdriver, adjust the by-pass screw (see Fig. 8). If changing from natural gas to LPG, completely tighten clockwise the screw, until a small regular flame is obtained.
By-pass screw
BY-pass diameters
Burner � By-pass in 1/100 of mm. 28 32 40
� Finally check the flame does not go out when quickly
turning the knob from the maximum position to the minimum position. This procedure can easily be carried out, anyhow the hob has been positioned or built in the working top. BURNERS TYPE OF GAS TYPE OF BURNER INJECTORS MARKS 1/100 mm
Auxiliary Semi-rapid Rapid - Fish kettle
NOMINAL POWER INPUT KW 3,0 2,0 1,0
REDUCED POWER kW
NOMINAL POWER 3 m /h 0,286 0,190 0,095 g/h -
NOMINAL PRESSURE mbar
Rapid (large)/Fish kettle NATURAL Semi-rapid (medium) GAS (Methane) Auxiliary (small)