thank u so much for this manual that was so cheap that i thought it was a scam but i gambled anyway because it was too good of a deal to pass up and behold,the manual has everything and details of everything even the screws and im still amazed and very happy with my manual .so take my word and jump on it before they realize how cheap they selling thier manuals..thank you so much for taking time to read my thoughts
SECTION 4 TEST MODE
CD SECTION
1. Entering CD test mode Connect power supply cord or insert dry batteries, short Test point (TEST-1) on the key board. (You need a moment for the short) (Power button is possible with both of ON or OFF to enter test mode).
R602
RF LEVEL and jitter check Test mode PLAY status Connection Point : CD board (Conductor side)
[CD BOARD] (Conductor side)
z
oscilloscope (AC range)
TP(RF)
The LCD display changes as in the diagram and the unit goes into test mode.
JW609
TP (RF) JW741 (VC)
cd
MEGA BASS
PGM
h
When you press the u key, the CD rotates and when you press theu key again, the CD plays (the track servo comes on) (but no sound is issued). Pressing the u key starts automatic adjustment and the value changes, but ignore this value.
[KEY BOARD] (Conductor side)
R607
R606
IC701
Check to see that the jitter is less than 9.0 nsec. and RF level is between 0.7 � 1.1Vp-p.
TEST-1
VOLT/DIV : 200mV (using 10:1 probe) TIME/DIV : 500ns
JW610
2. Exiting test mode With the unit in test mode, when you press the POWER button to OFF, power is off and test mode ends.
JW606
Q603
4
CN806
R603 1 R605 R604 S618
x
D602
x
TEST-1 SHORT : TEST MODE OPEN : NORMAL MODE