Complete service and operation manual. All schematics are there, all circuit boards AND add-on boards. Including exploded views ,component names and specifications. Also electrical and mechanical adjustment procedures are in this manual. This manual also covers the more advanced BR-S811E unit. Scan quality is fair and usable.
 ;
High quality scan of original Service Manual. Everything´s fine!
 ;
Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
 ;
The Service Manual received was helpful. The electronic information is exactly what I needed.
I recomend all of my friends about this technical page.
 ;
High quality scan of service manual. I am satisfied!
21HT-15S
DESCRIPTION OF SCHEMATIC DIAGRAM
SAFETY NOTE: 1. DISCONNECT THE AC PLUG FROM THE AC OUTLET BEFORE REPLACING PARTS. 2. SEMICONDUCTOR HEAT SINKS SHOULD BE REGARDED AS POTENTIAL SHOCK HAZARDS WHEN THE CHASSIS IS OPERATING. IMPOTANT SAFETY NOTE: PARTS MARKED WITH « ! » ( ) ARE IMPORTANT FOR MAINTAINING THE SAFETY OF THE SET. BE SURE TO REPLACE THESE PARTS WITH SPECIFIED ONES FOR MAINTAINING THE SAFETY AND PERFORMANCE OF THE SET.
NOTE: 1. The unit of resistance «ohm»is omitted (K=1000 ohms. M= Megaohm). 2. All resistors are 1/8 watt. unless otherwise noted. 3. All capacitors are µF, unless otherwise noted (P=
µµF).
4. The capacitor with Part No. RC-FZ9XXXBMNJ is designed to with stand 63V. 5. The capacitor with Part No. RC-FZ4XXXBMNJ is designed to with stand 50V.
SERVICE PRECAUTION: THE AREA ENCLOSED BY THIS LINE ( ) IS DIRECTLY CONNECTED WITH AC MAINS VOLTAGE. WHEN SERVICING THE AREA, CONNECT AN ISOLATING TRANSFORMER BETWEEN TV RECEIVER AND AC LINE TO ELIMINATE HAZARD OF ELECTRIC SHOCK. WAVEFORM MEASUREMENT CONDITION: Colour bar genetator signal of 70 dB from RF input.
CAUTION This circuit diagram is original one, therefore there may be slight difference from yours.
WAVEFORMS:
24
|
|
 |
> |
|