Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
 ;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar.
Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.
 ;
It's a grate service manuals.Have many details and the writing it's so clear.You have all you want in manual,nothing missing,belive me.I'm verry satisfied of this manual.
AV21BT7ENS / AV21BT7ENB AV21BT7EPS / AV21BT7EPB AV21BT7EES / AV21BT7EEB
Item 4:3 HORIZONTAL SHIFT Adjustment
Measuring instruments Signal generator
Test point
Adjustment part Adjust 12 ( 4 : 3 ) Adjust 23 ( 16 : 9 ) 1. 2. 3. 4.
Description Receive a RED test pattern. Set < 4 : 3 aspect mode >. Select < ADJUST 12 > from SERVICE MENU. Change horizontal shift till the picture is horizontally centered. Check whether this adjustment is correct after completing Service Mode Adjustment. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
VERTICAL SLOPE Adjustment
Signal generator
Adjust 13 ( 4 : 3 ) Adjust 24 ( 16 : 9 )
1. 2. 3. 4.
Receive a cross-hatch signal. Set < 4 : 3 aspect mode >. Select < ADJUST 13 > from SERVICE MENU. Change vertical slope till the size of squares on both the upper and lower part of test pattern become equal to the squares laying on the vertical centre of the test pattern. Check and readjust VERTICAL SLOPE item if the adjustment becomes improper after some other geometric adjustments are done. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
VERTICAL AMPLITUDE Adjustment
Signal generator
Adjust 14 ( 4 : 3 ) Adjust 25 ( 16 : 9 )
1. 2. 3. 4.
Receive a PAL test pattern signal. Set < 4 : 3 aspect mode >. Select < ADJUST 14 > from SERVICE MENU. Change vertical slope till horizontal black lines on both the upper and lower part of the test pattern become very close to the upper and lower horizontal sides of picture tube and nearly about to disappear. Check and readjust VERTICAL AMPLITUDE item if the adjustment becomes improper after some other geometric adjustments are done. 5. Set < 16 : 9 aspect mode >. 6. Adjusts with the step which is the same above from 3 to 4 about the 16 : 9 aspect mode, too.
14