Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
2-10. DP & DG Check 2-11. SCH Adjustment
2-10. DP & DG* Check
Measurement equipment Waveform/vector monitor Procedure 1. Supply a ramp signal (with chroma) from the signal generator (TSG-170A) to the ANALOG IN connector. 2. Set the waveform/vector monitor as follows. MODE : VECTOR DP & DG measuring INPUT : CH A n To change to the DP & DG measuring display, push the measure button and touch DP & DG item on the display (the display is a touch panel). Measuring point : ANALOG OUT connectors (BKPF-102 connector panel)
2-11. SCH Adjustment
Measurement equipment Oscilloscope Procedure 1. Supply 75% (SMPTE) color bars signal from the signal generator (TSG-170A) to the ANALOG IN connector. 2. Set the oscilloscope as follows. CH2 : 2 V/DIV AC TIME : 50 ns/DIV TRIG : CH1 (ANALOG OUT) or CH4 (EQ OUT) Measuring point : TP102 (E-4)/AD-147 Adjustment point : 1RV3 (E-4)/AD-147
A
DP DP < 1% TP102
50%
DG DG < 1%
A = 70 ±5 ns
*DP : Differential Phase
DG : Differential Gain 2-6 (E)
BKPF-101A
|
|
 |
> |
|