Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is quiet a rare manual, I Have looked for this manual for quiet a while now, I have finally found it here. I believe this is the only place they have them in a very nice scan, Excellent guide: very clear, enabling us to print readable diagram overall it is great to have this manual available for purchase. This is a complete service manual no pages are missing. Thanks
 ;
This SM is quiet scarce and hard to find it is an excellent Service manual, very clear to read and to print schematics and diagrams, Hi quality, Complete manual with no pages missing. I am very pleased with the manual and the fast service I have received. Great place to shop.
Good luck finding you manual...
 ;
Quick delivery, the document was usefull, although the copy was i little bit unclear in the details.
 ;
A complete and well done copy of the manual, at a not expansive price!
The delivery of the manual is very fast.
Thank you for all
 ;
Perfect quality. Was able to fix speed drifting on my Sansui Turntable using the service manual instructions for PLL adjustment.
2. Installation of the Board
2. Set the switches and connectors on the board (BKSI2041 and BKSI-2042 only). 3. Attach the model label supplied with the connector panel in the chassis near the slot to install the board. n After the connector panel is inserted into a slot, the slot label cannot be seen. 4. Insert the connector panel to the matching slot and secure the panel by the two screws which installed the blank panel to the SIU-80.
Information for inserting slot BKSI-2041 Insert this connector panel into the No.1 slot. Use this panel a pair with the root controller BKSI-2040 (plug-in board) which is inserted into the No.1 slot in the front of SIU-80. m � When Server Management System has the multiple SIU80s installed the IDC boards, the root controller BKSI2040 is installed in the only one of SIU-80s. Therefore the other SIU-80s does not necessarily pair BKSI-2041 with BKSI-2040. (Refer to �3-2. Connection of IDC Link�.) � There�s no need to pair this panel with the root backup BKSI-2040 which installed in the No.2 slot in the front of SIU-80. In this case, the No.2 slot in the rear of SIU-80 is empty. BKSI-2042/2043/2044 These connector panels are inserted into any slot No.1 to No.8 in the rear of SIU-80. Use each panel a pair with device controller BKSI-2040 which is inserted in the front slot of SIU-80. n Insert these panels into any slot No.3 to No.8, when the root backup BKSI-2040 is installed in the No.2 slot in the front of SIU-80.
SIU-80
Model label Connector panel BVTT 3X6
5. When remove the connector panel, turn the power off and remove the power cord plug from the receptacle, and then remove the panel in the reverse order of steps 1 through 4. n To remove the connector panel, pull the right and left handles on the connector panel until the connection with the mother board is sufficiently loose, then pull out the connector panel gently.
BKSI-2040
1-5 (E)
|
|
 |
> |
|