Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
CFD-S26 SECTION 4 MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback head pinch roller erase head rubber belts capstan idlers 2. Demagnetize the record/playback head with a head demagnetizer. (Do not bring the head magnetizer close to the erase head.) 3. Do not use a magnetized screwdriver for the adjustments. 4. The adjustments should be performed with the rated power supply voltage (9V) unless otherwise noted. Torque Measurement Mode FWD Torque meter CQ-102C Meter reading 2.95 � 6.86 mN � m (30 � 70 g � cm) (0.42 � 0.97 oz � inch) 0.15 � 0.53 mN � m (1.5 � 5.5 g � cm) (0.021 � 0.076 oz � inch) CQ-201B more than 5.88 mN � m (more than 60 g � cm) (more than 0.83 oz � inch) more than 5.88 mN � m (more than 60 g � cm) (more than 0.83 oz � inch) Tape Speed Adjustment Procedure: Mode: playback
test tape WS-48A (3 kHz, 0 dB) 32 � set i jack (J321) digital frequency counter
SECTION 5 ELECTRICAL ADJUSTMENTS
TAPE SECTION 0 dB = 0.775 V
� Standard Output Level Output terminal load impedance output signal level � Test Tape Type WS-48A Signal 3 kHz, 0 dB Used for tape speed adjustment HP OUT 32 � 0.25 V (�10 dB)
FWD Back Tension
CQ-102C
FF
REW
CQ-201B
Adjust so that the value on the digital frequency counter is 3,000 Hz. Tape Tension Measurement Mode FWD Tension meter CQ-403A Meter Reading more than 100 g (more than 3.53 oz) Specification Value: Digital frequency counter 2,940 to 3,060 Hz Adjust so that the frequency at the beginning and that at the end of tape winding are between 2,970 to 3,030 Hz. Adjustment Location:
Tape speed adjustment control inside motor
15