Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
This is a high quality manual with clear schematic and components layout diagrams ; with service procedure included.
 ;
This service manual for the Kenwood KT-990D was reproduced really well ,is very legible and manual is complete.Combined with the low price paid,in the future,I will be checking Owner-Manuals.com any time I need a manual.
 ;
When I purchased this manual I had my doubts regarding the quality as the price was so reasonable as compared to other outlets.
The manual itself is of high standard the print is very clear as are the diagrams. Obviously with the diagrams one has to zoom in otherwise it is to small to be able to read.
Overall I am very pleased with the company who delivered as they said and with the manual they supplied.
I occasionally require a manual and now having registered with this company I shall order from them in the future.
 ;
I was at first dubious about payiong for downloaded manuals but having done so, I was extremely impressed with quality of the two manual I ordered, well worth the small price I paid.
I would highly recommend these to my friends.
 ;
reasonable price for the schematic - the service is perfect, all as expected and pointed by instructions - good scan of the original plans - thank you!
Back-up Battery Before replacing the back-up battery, note the following precautions: � Do not remove the back-up battery from the CSF Unit while main batteries are removed. � Be sure to replace the back-up battery at least once a year. Otherwise, you run the risk of losing data stored in memory. 1. Press OFF to switch power OFF. 2. Remove the screws that hold the back-up battery compartment cover in place, and remove the cover.
RESET
Back-up battery compartment cover 3. Insert a thin, pointed object into (A) and remove the old battery. (A)
CR2025 lithium battery
4. Insert a new battery into the unit, making sure that the positive (+) side of the new battery is facing up (so you can see it). 5. Replace the battery compartment cover and secure it by tightening its screw. � Be careful that you do not over tighten the screw.
5.
RESET OPERATION
1. Press ON to switch power ON. 2. Press the RESET button with a thin, pointed object.
RESET button
RESET
Warning! The next step deletes all data stored in the CSF Unit's memory. Make sure that you really want to delete the data before you continue! 3. Press 1 to select ALL RESET.
Note � The above message always appears in English, regardless of the system language setting.