Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Thank you for your manual It has the basic things to and i use the Oszi for Longer Time.
THX
 ;
Actually, I was looking for this information for 3 years!...now thanks to you, the manual is on my hands and of great help, cause I understand now where I was doing wrong connections and wires...excellent, I'll be back to you if in need, thank you.
 ;
This manual covers the main equipment features only. While it also includes the procedure for saving and loading from the now long obsolete memory cards it does not mention the how to operate with the optional floppy drive interface so I am still at a loss about how to use this! Note that there is a separate manual covering the MIDI interface and programming via the keyboard, not included in this download. You will also need to get hold of this if you want to use the MIDI interface properly. Basically there is little difference between this manual and the free to download manual for the similar PR60 model.
 ;
Good list of manuals. I found a very rare one and easily get. Should be promptly to download, as we must to wait hours even after confirmed payment.
 ;
The manual was properly scanned and perfectly readable. The only small problem is that I couldn't use my dear Ctrl + F to find a word I needed.
YH Adjustment (VR2 for vertical dynamic convergence) 1. Apply a crosshatch pattern. 2. Adjust contrast and brightness customer controls to obtain a correct picture. 3. With a driver Adjust VR2 (located in deflection yoke board Fig. 19) to obtain a proper corvergence at left and right side of the screen. (see Fig. 14)
Permalloy convergence corrector strip (part No. 0FMK014ZZ)
This strip is used in some sets to match the yoke and CRT for optimum convergence. If the yoke or CRT is replaced, the strip may not be required. First converge the set without the strip and observe the corners. If correction is needed: 1. Place strip between CRT and yoke, in quadrant needing correction. Slowly move it around for desired results. 2. Press adhesive tightly to the CRT and secure with tape.
DAF adjustment
Preparation: 1. Apply a crosshatch pattern. 2. Set user controls, bright to center and picture to max. 3. Connect a frequency counter to TPD10. Procedure: 1. Connect channel one of the oscilloscope with 100x1 probe to TPP33 (pin-1 T1551). 2. Connect channel two of the oscilloscope with 10x1 probe to CRT HEATER (L-Board). 3. Adjust �HDAFP� so both waves are in the same position. 4. Adjust �HDAFW� so TPP33 is 1.5 ± 0.5kVpp.
TPP33
G B&R G B&R
G B&R G B&R
Figure 14. VR2 Adjustment (YH)
XV Adjustment (precise adjustment)
1. Apply a crosshatch pattern. 2. Adjust contrast and brightness customer controls to obtain a correct picture. 3. With a driver adjust the coil located in deflection yoke board to obtain a proper convergence horizontally.
B&R G B&R G
HEATER PIN
B&R G B&R G
Figure 16. DAF adjustment
Figure 15. XV adjustment
Note:
Apply a red pattern and confirm purity, if purity is poor, repeat purity adjustments.
- 17 -
|
|
 |
> |
|