At first I thought there had been a mix up as I required the service manual for the cassette unit and the one supplied was for the CD unit. However when I scrolled further down I realised that both had been scanned together! This enabled me to dismantle and repair the cassette unit as intended and I also have a copy of the manual for both the CD and graphic equaliser units should I ever need them. Thanks very much for a great service.
 ;
Excelent service, the manual is complete, very cheap and fast
Alberto
YH Adjustment (VR2 for vertical dynamic convergence) 1. Apply a crosshatch pattern. 2. Adjust contrast and brightness customer controls to obtain a correct picture. 3. With a driver Adjust VR2 (located in deflection yoke board Fig. 19) to obtain a proper corvergence at left and right side of the screen. (see Fig. 14)
Permalloy convergence corrector strip (part No. 0FMK014ZZ)
This strip is used in some sets to match the yoke and CRT for optimum convergence. If the yoke or CRT is replaced, the strip may not be required. First converge the set without the strip and observe the corners. If correction is needed: 1. Place strip between CRT and yoke, in quadrant needing correction. Slowly move it around for desired results. 2. Press adhesive tightly to the CRT and secure with tape.
DAF adjustment
Preparation: 1. Apply a crosshatch pattern. 2. Set user controls, bright to center and picture to max. 3. Connect a frequency counter to TPD10. Procedure: 1. Connect channel one of the oscilloscope with 100x1 probe to TPP33 (pin-1 T1551). 2. Connect channel two of the oscilloscope with 10x1 probe to CRT HEATER (L-Board). 3. Adjust �HDAFP� so both waves are in the same position. 4. Adjust �HDAFW� so TPP33 is 1.5 ± 0.5kVpp.
TPP33
G B&R G B&R
G B&R G B&R
Figure 14. VR2 Adjustment (YH)
XV Adjustment (precise adjustment)
1. Apply a crosshatch pattern. 2. Adjust contrast and brightness customer controls to obtain a correct picture. 3. With a driver adjust the coil located in deflection yoke board to obtain a proper convergence horizontally.
B&R G B&R G
HEATER PIN
B&R G B&R G
Figure 16. DAF adjustment
Figure 15. XV adjustment
Note:
Apply a red pattern and confirm purity, if purity is poor, repeat purity adjustments.