Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
exactly as they say. Within 24 hours the link to the pages and offcourse it was the right service manual. Super and thanks
 ;
The manual was exact the thing that was promised. My old car stereo is working again thanks to the information supplied.
 ;
I PURHASED THIS PRODUCT BECAUSE I WAS HAVING PROBLEMS WITH MY CDR20 HARMAN KARDON RECORDER. WHICH I PURCHASED NEW 12 YEARS AGO. AFTER REVIEWING THE MANUAL, I WAS ABLE TO ADJUST THE TENSIONER IN THE SYSTEM. WORKS LIKE A CHAMP!.
SAVED ME AT LEAST 100.00 WHICH WAS WHAT A SERVICE REPAIR STATION WANTED. GREAT MANUAL EASY TO READ. SPECIALLY AFTER I PRINTED THE PAGES WHICH DEALT WITH MY RECORDER. THANKS A LOT!!!!!!!!
 ;
You can fully trust on this one!
All the schematics are very crear an in one piece per page
 ;
I have never bought a service manual which is as competely readable as this althogh it was a scanned pdf. Thank you for this succesful manual also cheaper than other sites.
POWER SUPPLY BLOCK
[Head Voltage Adjustment] Before performing this adjustment, print the stair-step pattern (Note 2) two times continuously with the old head (Note 1) or normal unit. The second print will be used as a sample of the print density.
Note 1: Only when the old head (faulty head) is not entirely damaged with black or white lines. Note 2: To print the stair-step test pattern, turn on the power switch while pressing the S1707 (CAPTURE) and S1717 (ENTER) on the SW39 board. (Press the S1707 (CAPTURE) and S1717 (ENTER) until a peep is heard.) Set the S1701 (Rotaly switch) to the position, and press the S1706 (print), then the print will start. Mode Signal Measuring points Measuring instrument Adjustment part Specification Test mode (Note 2) Test pattern (Stair-step) +: CN1943 2 pin (MD-39 board) �: CN1943 3 pin Digital Voltmerter VR201 Print density should be the same as the sample
Fig. 4-4 Stair-step pattern
* VR201 is in the power block (1-468-364-11). Adjustment Location:
Adjustment Procedure: (1) To print the stair-step test pattern, turn on the power switch while pressing the S1707 (CAPTURE) and S1717 (ENTER) on the SW-39 board. (Press the S1707 (CAPTURE) and S1717 (ENTER) until a peep is heard.) Set the S1701 (Rotaly switch) to the position, and press the S1706 (print), then the print will start. (2) After printing, repeat (1) immediately. (3) Compare the second printed pattern density with that of the sample, and if the density differs, perform the following adjustment. (4) Adjust VR201 according to the print density. If darker than the sample: Decrease the head voltage. If lighter than the sample: Increase the head voltage. (5) Print the stair-step pattern two times continuously. (6) Compare the second printed pattern density with that of the simple, and if the density differs, repeat steps (3) to (6).
Note: Only one print is required after the second time.
power block
VR201
(7)
Turn off the power switch.