Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Categories
Information
Featured Product
Home >> HAMEG >> HM81343 Owner's Manual
 
 0 item(s) in your cart 

HAMEG HM81343
Owner's Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Download
  • PDF Format
  • Complete manual
  • Language: English, German
Price: $4.99

Description of HAMEG HM81343 Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file after You purchase it.

Owner's Manual ( sometimes referred to as User's Guide or User's Manual ) contains information on how to use Your device. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English, German

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 VP-A30 SAMSUNG Owner's Manual by Johan Lund;
My first manual from Owner-Manuals.com but not the last! I am very satisfied with the easy ordering and promt delivery of a manual I did not find anywhere else.
 PE1644 PHILIPS Owner's Manual by Thijs Werkman;
This manual is very helpfull to use the Power Supply. All technical information has been available. For service use the circuit diagrams are very good. Thanks .
 SATELLIT 2100 GRUNDIG Owner's Manual by Jean-Robert LAROCHE;
Very comprehensive document which is a must-have for any Satellit 2100 owner whose set up is somewhat intricate. Due to the bad quality of the pictures that are rather dark and a bit blurred I gave 4-star feedback.
 SA-GX505 TECHNICS Owner's Manual by David Salars;
The manual was missing 2 pages but when I presented the problem to the company they made every attempt to get the 2 pages to me, when they couldn't they refunded my money. A very pleasing and easy transaction. The manual they provided was the original, it was concise and to the point. I plan to do business with this company again when should the need arise.
 CT-W502R PIONEER Owner's Manual by tom dolfin;
The owners manual is very good. all my how to questions were answered in detail.

Text excerpt from page 40 (click to view)
Operating controls
turns the current modulation frequency. The instrument sends back a string representing a NR3 decimal number. :PM:INTern:SHAPe SIN | SQU :PM:INTern:SHAPe? (9) (10)

PSK
Commands in order to modify PSK parameters. Syntax: :PSKey :SOURce EXT (1) :PSKey :SOURce ? (2) Sending line (1) the modulation source can be changed (for this unit version always EXT). Sending line (2) the instrument returns the PSK source. It sends back the string EXT (not EXTERN). :PSKey :PH0 <NUM> :PSKey :PH0? :PSKey :PH1 <NUM> :PSKey :PH1? (3) (4) (5) (6)

Sending line (9) the shape of the internal modulation signal can be changed. The parameters are: SIN for a sine signal, SQU for square. Sending line (10) the instrument returns the current shape. The instrument sends back the same strings as the corresponding command parameters above. :PM:STATe 0 | OFF | 1 | ON :PM:STATe? (11) (12)

Sending line (11) the PM can be turned on or off. The PM is turned on by sending the parameters 1 or ON and it is turned off by sending 0 or OFF (if present). Sending line (12) the instrument returns the current PM state. The instrument sends back 0, if no PM is in progress, and 1, if PM is present. :PM:EXTern:COUPling AC | DC :PM:EXTern:COUPling? (13) (14)

Sending line (3) and (5) the two phases PH0 and PH1 can be changed. The <NUM> parameter is a NR2 number (see paragraph Syntax conventions). No unit must follow the number, the current unit is the default one. If the value has an accuracy higher than the resolution, the number is rounded to the corresponding digit. Sending line (4) and (6) the instrument returns the two phases PH0 and PH1. It sends back a string representing a NR2 decimal number (without unit). :PSKey :UNIT RAD|DEG :PSKey :UNIT? (7) (8)

Sending line (13) the external PM modulation is set to AC or DC mode. Sending line (14) the instrument returns the current state. The instrument sends back the same strings as the corresponding command parameters above. Example: :PM:UNIT DEG; DEV 120; INT:FREQ 1E+3; SHAP SIN; STATE 1

Sending line (7) the current unit can be changed. Two para-meters are possible: RAD for radian or DEG for degree. Sending line (8) the instrument returns the current unit. It sends back the same string as the corresponding command parameters above. :PSKey :STAT 0|OFF|1|ON :PSKey :STAT? (9) (10)

FSK
Commands in order to modify FSK parameters Syntax: :FSKey :SOURce EXT (1) :FSKey :SOURce ? (2) Sending line (1) the modulation source can be changed (for this unit version always EXT). Sending line (2) the instrument returns the FSK source. It sends back the string EXT (not EXTERN). :FSKey :F0 <NUM> :FSKey :F0? :FSKey :F1 <NUM> :FSKey :F1? (3) (4) (5) (6)

Sending line (9) the PSK can be turned on or off. The PSK is turned on by sending the parameters 1 or ON, and it is turned off by sending 0 or OFF (if present). Sending line (10) the instrument returns the current FSK state. The instrument sends back 0, if no PSK is in progress, and 1, if PSK is present. Example: :PSK:SOUR EXT ; UNIT RAD ; PH0 0 ; PH1 10 ; STAT ON

SWEEP
Commands in order to modify SWEEP parameters. Syntax : :FREQuency:MODE SWEep (1) :FREQuency :MODE FIXed | CW (2) :FREQuency :MODE ? (3) Sending line (1) the SWEEP can be turned on. Sending line (2) the SWEEP can be turned off, if SWEEP is present. Sending line (3) the instrument returns the current SWEEP state. It sends back SWE, if SWEEP is in progress, and FIX, if no SWEEP is present. :FREQuency:STARt <NUM> :FREQuency:STARt? :FREQuency:STOP <NUM> :FREQuency:STOP? (4) (5) (6) (7)

Sending line (3) and (5) the two frequencies F0 and F1 can be changed. The <NUM> parameter is a NR1 or NR2 or NR3 number (see paragraph Syntax conventions). No unit must follow the number, Hz unit is the default one. The value is rounded to the resolution. Sending line (4) and (6) the in-strument returns the two frequencies F0 and F1. It sends back a string representing a NR3 decimal number. :FSKey :STATe 0|OFF|1|ON :FSKey :STATe? (7) (8)

Sending line (7) the FSK can be turned on or off. The FSK is turned on by sending the parameters 1 or ON, and it is turned off by sending 0 or OFF (if present). Sending line (8) the instrument returns the current FSK state. The instrument sends back 0, if no FSK is in progress, and 1, if FSK is present. Example: :FSK:SOUR EXT ; F0 400E+6 ; F1 410E+6 ; STAT ON
40

Sending line (4) and (6) the two frequencies START and STOP can be changed. The <NUM> parameter is a NR1 or NR2 or NR3 number (see paragraph Syntax conventions). No unit must follow the number, Hz unit is the default one. The value is rounded to

Subject to change without notice

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EV-S1000E SONY
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

MECABLITZ 60 CT4 METZ
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 0.946 - Number of Queries: 129 - Query Time: 0.44