Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Quick service response. A useful and very rare service manual with all details. I recomend this service.
 ;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
 ;
The manual was well-scanned and easy to read. As an added bonus, the Operator's Manual was bundled with the Service Manual!
I'd definitely use owner-manuals.com again.
 ;
Finally, i found one website, where i can download this service manual , and fix my hifi. The service manual is very good, and easy to download and to print.
SECTION 4 ADJUSTMENT Please refer to "HR-XVC29SUS No.YD052" about this section except a written item.
4.1 Electrical adjustment (HR-XVC29SUM ONLY) Note: The following adjustment procedures are not only necessary after replacement of consumable mechanical parts or board assemblies, but are also provided as references to be referred to when servicing the electrical circuitry. In case of trouble with the electrical circuitry, always begin a service by identifying the defective points by using the measuring instruments as described in the following electrical adjustment procedures. After this, proceed to the repair, replacement and/or adjustment. If the required measuring instruments are not available in the field, do not change the adjustment parts (variable resistor, etc.) carelessly. 4.1.1 Syscon circuit Notes: � When perform this adjustment, remove the Mechanism assembly. 4.1.1.1 Timer clock
(A1) (B) (C) (D1) (D2) (D3) � � � � � � No signal EE Frequency counter IC3001 pin 29 IC3001 pin 31 IC3001 pin 32
Signal Mode Equipment Measuring point
(D4) � IC3001 pin 25 Adjustment part (F) � C3018 (TIMER CLOCK) Specified value (G1) � 1024.008 ± 0.001 Hz (976.554 ± 0.001 µsec)
(1) Connect the frequency counter to the measuring point (D1). (2) Connect the short wire between the short point (D2) and (D3) to GND. (3) Short the point (D4) and GND in order to reset the microprocessor of the Syscon. (4) Disconnect the short wire between the short point (D3) and GND. (5) Adjust the Adjustment part (F) so that the output frequency becomes the specified value (G).
SECTION 5 TROUBLESHOOTING Please refer to "HR-XVC29SUS No.YD052" about this section.
1-4 (No.YD071)
|
|
 |
> |
|