Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
muy buen manual por lo completo de este algunos esquemas estan muy divididos lo que hace algo dificil el seguimiento.
 ;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
 ;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
 ;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
ADJUSTMENT
A MAIN C.B
1
2
2
VOLUME VR101
SFR 301
1
2
3
IC301
TP2 (L-CH)
TP1 (R-CH)
2
4
2
GND
IC701
PHONES J101
1
<TAPE PLAYER SECTION>
1. Tape Speed Adjustment Settings : � Test tape : TTA � 100 (Tape center) � Test point : Phones Jack (J101) � Adjustment location : SFR301 � Dolby : OFF � MSP : CLASSIC � DSL : OFF � Tape selector : NORMAL(AUTO) � Volume : MAX Method : Play back (FWD) the test tape and adjust SFR301 so that the frequency becomes 3015Hz ± 10Hz. Then confirm WOW is less than 0.50%.
PRACTICAL SERVICE FIGURE
<TAPE SECTION>
Tape speed : Wow : Take-up torque : F.F torque : REW torque : Back tension : S/N ratio : Distortion : Noise level : 3015Hz ± 50Hz Less than 0.55% (RMS) 20 ~ 30g-cm (FWD) 70 ~ 150g-cm 70 ~ 150g-cm 1.0 ~ 3.0g-cm (FWD) More than 42dB (PB, DC) Less than 3.0% (PB, DC) Less than 3.0mV (Vol MAX, PB, DC) Less than 0.4mV (Vol MIN, PB, DC) 63Hz + 3 / � 5dB ~ 8kHz + 4 / � 4dB (NORMAL) 63Hz + 3 / � 5dB ~10kHz + 4 / � 4dB (CrO2) TTA � 100 TTA � 200 TTA � 320(NORMAL) TTA � 310(CrO2)
2. Dolby Level Adjustment Frequency response : Setting : � Test tape : TTA � 200 � Test point : TP1(RCH),TP2(LCH) � DSL : OFF � Tape selector : NORMAL Test tape : � Dolby SW : OFF � Volume : MIN � Adjustment points : Soldered patterns 1 � 4 Procedure : Short the patterns via solder as showen in the table so the Dolby NR level is 24.5mV ± 1.0dB. Adjust so the specifications are satisfied in both the forward and reverse directions. Connect 10mF /16V coupling capacitors between test points and test equipment (connect the positive terminals to the test points). SOLDER PATTERN 1 � 4 STANDARD : 24.5 ± 1.0dB SOLDER POINT INCRESE LEVEL 1 only +1dB Lch
2 1 3
only and 2
+1.5dB +2.5dB +1dB +1.5dB +2.5dB
Rch
only 4 only 3 and 4
1 1
|
|
 |
> |
|