There are currently no product reviews.
 ;
El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
HT-R330 OPERATION CHECK-2
SPEAKER PROTECT-2 (CURRENT DETECTION)
[When] 1. Exchange power transistors (Q6050 - Q6065). 2. Exchange amplifier PC board ass'y (NAAF-8523). [Procedure] <Note> No input. Do not check two or more channels at the same time. Do not connect dummy load to speaker terminals for seconds 2 or more. 1. Press and the hold down the CD button , then press the STANDBY/ON button when the unit is Power ON. " Test - _ " is displays it only for 5 seconds.
Te st - _
Blinks
2. Press the VIDEO 3 button, while the character of " Test - _ " is displayed. Unit will be in the state of " Test-4-00 ".
Te st - 4-00
3. Repeatedly press TONE+ button until the character of " Test-4-35 " is displayed.
Te st - 4-35
4. Connect the Dummy load of 3 ohms to the Front Lch speakers terminal. At this time, check the speaker relay is not turned off.
Te st - 4-35
5. Connect the dummy load of 1 ohm to the Front Lch speakers terminal. At that time, you check the speaker relay is turned off and " Protect " is displayed.
P rotect
Disconnect the dummy load at once when check the display of " Protect ".
Te st - 4-35
6. Check other channels according to the same procedure. 7. Press the STANDBY/ON button.
Turn off
Clear
|