Wanting to repair a neighbours tape recorder I needed the necessary information, it makes it easier. Although the service manual is described as "Language : English" To my dismay I found that it is entirely written in German, a language I do not understand. At least I now have the schematics which will help of sorts. I may not use this service again due to the laguage difficulty after all when it states English you do not expect it to be entirely in another language.
 ;
GOOD SERVICE MANUAL.I ALWAYS BUY THERE IF I FIND WHAT I AM LOKING
 ;
Good quality (clearly readable) manual, I'm glad I could find it here, at a bargain price!
 ;
Speedy transaction with a quick download. Awesome hassle-free service.
 ;
very poolite and healpful secure transaction thanks allot
October 9th, 1995
APPENDIX B. OPTICAL ADJUSTMENT (ELECTRICAL)
18. Move the 1st carriage to the white chart position. Then press the Enter key.
<<<< AGC=27 >>>> <<<< Absolute white level (W1) >>>> Ajust VR3 : <W0X> == 0 +/- 3 **** Image Data (#3684) **** [ Exit : �!� key ] 003,003, 085,085 (082,082 <+>000) [082] [X] Ave-(O:082,E:082 <+>000) [082]
19. Adjust VR3 on the SBU until the value of X is within the required range. (In the example screen above, the value on the bottom line below the X must be 0 +/- 3.) Then input !.
<<<<<< EXIT >>>>>> [ Finish white odd even ajustment!! ] [ Next : Hit Enter Key !! ]
20. Press the Enter key. This ends the White Level Difference Adjustment and starts the Absolute White Level Adjustment.
************************************** **** AJUST WHITE LEVEL (ABSOLUTE) **** ************************************** ---- Put the White Chart on the Lamp position !! ---- << Then , Hit Enter Key >>
21. Make sure that the 1st carriage is at the white chart position. Then press the Enter key.
<<<< AGC=27 >>>> <<<< Absolute white level (W1) >>>> Ajust VR4 : [X] == 220 +0 /-10 **** Image Data (#3584) **** [ Exit : �!� key ] 002,002, 219,217 (217,215 <+>002) [216] [X] Ave-(O:217,E:214 <+>002) [215]
22. Adjust VR4 on the SBU until the value of X is within the required range. (In the example screen above, the value on the bottom line below the X must be 220 +0 / - 10.) Then input !.
<<<<<< EXIT >>>>>> [ Finish white level (absolute) ajustment!! ] [ Next : Hit Enter Key !! ]
23. Press the Enter key. This ends the Absolute White Level Adjustment and starts the Relative White Level Adjustment.
************************************** **** AJUST WHITE LEVEL (RELATIVE) **** ************************************** ---- Put the White Chart on the Lamp position !! ---<< Then , Hit Enter Key >>
B-7