Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
 ;
I will definitely be back for more information when I need it.
 ;
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
 ;
The manual is useful for trouble shooting for an old instrument. It saved money,and let me enjoy DIY.
 ;
Perfect source of information for replacing the HDD and performing general diagnostics.
KTC-V500E/N/P
ADJUSTMENT
X25 Circuit Adjustment Specification (M : For the Other Markets) Item
1. Video detection co il adjustment L303
Adjustment method/Adjustment value
1. Turn VR301 [RF-AGC] fully to the right. 2. Apply DC2.0V to TP [IF AGC] (IC300 pin36). 3. Feed fo=38.0MHz, Mod=1kHz, AM60%, Level=100dBµ into TP [IF] (A100 pin8). 4. Observe the TP [VIDEO] (IC300 pin8) waveform on an oscilloscope and adjust L303 for maximum level.
Conditions
No ANT signal If the waveform is clipped, slightly increase the DC voltage. AC range
Maximum
2. Audio detection coil adjustment L300
1. Turn VR301 [RF-AGC] fully to the right. 2. Feed fo=31.5MHz, No Modulation, Level=94dBµ into TP [IF] (A100 pin8). 3. Connect a voltmeter to TP [SIF] (both ends of R314) and adjust L300 for 0V ± 0.01V.
No ANT signal
3. S-METER adjustment VR300 4. RF AGC adjustment VR301
1. Turn VR301 [RF-AGC] fully to the right. 2. Feed a 30dBµ CHINA 9CH color bar RF signal into the ANT input terminal. 3. Audio (P/S ratio -6dB) no modulation. 4. Connect a voltmeter to CN300 and adjust VR300 [SMET] so it reads 3.5V ± 0.05V. 5. Set the RF signal to 70dBµ and adjust VR301 [RF-AGC] so that the voltmeter connected to CN300 reads 4.8V ± 0.05V.
Postpone adjusting VR301 to prevent AGC having effect at 30dBµ. Ensure the RF AGC adjustment is performed after the S-METER adjustment. No ANT signal Test mode
5. Diversity free run frequency adjustment VR400
1. Connect a frequency counter to CN400. 2. Using the remote control unit TV/NAVI button, switch to adjustment mode. 3. Adjust VR400 [15kHz] so as to obtain 15625 ± 100Hz.