Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
 ;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
 ;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar.
Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.
KV-ES38M31/ES38M61/ES38M90/ES38M91
RM-916
4 BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned, then use the BMC magnet to adjust in the manner described below.
RG B R G B R GB
(2) Dynamic Convergence Adjustment Preparation: � Before starting this adjustment, adjust the horizontal static � convergence and the vertical static convergence Set the PICTURE and BRIGHTNESS to normal.
1. Adjust TLH. (TLH correction piece) 1 Receive the dot/hatch pattern signal and adjust picture quality by the menu. 2 Correct horizontal mis-convergence of red and blue of both sides on the X axis. When red is outside insert BMC magnet to right side (THL+)
R G B R G B
R G
B
views from DY neck. And when blue is outside, insert it to left side (THL�) and take both sides.
RB (B) (R) B R TLH + (R) (B) TLH -
5 Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust [PICTURE] to [MIN] and [BRIGHTNESS] to [STANDARD] . 2. Adjust the Y separation axis correction magnet on the neck assembly so that the horizontal lines at the top and bottom of the screen are straight.
Blue Red
2. Adjust V-TILT-TLV. Correct the vertical mis-convergence of red and blue of vertically sides on the Y axis. 3. Adjust YCH. Adjust horizontal mis-convergence of red and blue of vertically sides on the Y axis. Mentioned above steps 2 to 4 are adjusting respectively perform minuteness tracking.
Neck assy
Neck assy
YCH H-TRP
Red Blue
TLV
VM board VM board
BMC magnet
C board
RV9001
Note 1. The Red and Blue magnets should be equally far from the horizontal center line. 2. Do not separate the Red and Blue magnets too far. (Less than 8 mm)
VM board