Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
- Very good scan quality, PERFECT!
- Sehr gute scan Qualitaet, empfehlenswert!
Wolfgang Sundhaus
 ;
Good site, works ok and you get what you order, no problems experienced, got my manual within a day. A++++
 ;
Original well scanned manual. Got the job done. Microwave problem found & corrected. For $5 and a new magnitron from ebay, it was a cheap and good the first shot fix. Electrical schematics allowed me to mage sure every thing else was ok before cutting and order for parts. Hard to live without.
 ;
I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
 ;
Manual was reasonably easy to follow. I am not an engineer or know much about electronics but with the manuals help I was able to figure out the problem, identify the part required for the repair. Replacement part cost around $30. Whilst replacing the part I was telling myself, "this aint gonna work cos it seems far too easy". Took about 15 minutes to do and my plasma TV works a treat. Would never have been able to do this without the service manual.
M-AX10
3.1 Key Inputs
A key input becomes valid after 40 ms, to eliminate chatter. The ATT.THROUGH key input from OFF to ON becomes valid when the key is held pressed for 2 seconds.
Port 16 (SPRYH)(Pin16) is set to "L" 10 ms after ATT.THROUGH switching signal input, and relay is set to OFF. After another 30 ms, the INDICATOR port is processed. Port 31 (FMT)(Pin31) is set to "H," and muting is set to ON. Switching process is performed 100 ms after ATT.THROUGH switching signal input. When switching ATT THROUGH from ON to OFF: Data transfer to the DAC IC is performed 2 seconds after the key input. When switching ATT.THROUGH from OFF to ON: Port 2 (LD), port 3 (CLK), and port 4 (SRD) are fixed to "L" before DACVR (pin 13) is set to "L," 30 ms after relay becomes OFF. (See "6. DAC Volume Transfer."(P.49))
3.2 Switch inputs
The MODE switch (rotary switch) setting is read when the power is turned on. The switch operation with POWER ON is invalid. (See "7. WARNING."(P.50))
4. KEY PROCESSING (IC901)
4.1 ATT.THROUGH Switching
The ATT.THROUGH key input from ON to OFF becomes valid when the key is held pressed for 2 seconds. Any other key input during these 2 seconds is invalid. When switching from OFF to ON, the key input becomes valid at normal timing. After another 2 seconds, port 31 (FMT)(Pin31) is set to "L," and muting is set to OFF. After another 3 seconds, port 16 (SPRYH)(Pin16) is set to "H," and relay becomes OFF.
Key input valid
EEPROM writing
1
Relay
2 10 msec 3 5 sec
Mute
4 40 msec 5
LED ON/OFF processing 2 sec
6 40 msec
Switching
7
100 msec VOL. processing (ON � OFF)
8 2 sec
VOL. data line processing (OFF � ON)
9
Silent processing
0 200 msec
Fig.2 Timing chart when ATT. through key is pressed
47
|
|
 |
> |
|