|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
 ;
Received a quick response, material was exactly what it was supposed to be. The service did everything I expected it to do. would use service again.
 ;
Good scan, great price, but almost the same with the SV260 service manual.
 ;
This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
 ;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
 ;
Good manual contains all it takes to update, repair,these types of mixers.Thanks.
 ;
Great service. Fast response. High quality scan. Good price.
Thank you very much!!!
Oleg S.
DISASSEMBLY INSTRUCTIONS
2. REMOVAL OF ANODE CAP
Read the following NOTED items before starting work. * After turning the power off there might still be a potential voltage that is very dangerous. When removing the Anode Cap, make sure to discharge the Anode Cap's potential voltage. * Do not use pliers to loosen or tighten the Anode Cap terminal, this may cause the spring to be damaged. REMOVAL 1. Follow the steps as follows to discharge the Anode Cap. (Refer to Fig. 2-1.) Connect one end of an Alligator Clip to the metal part of a flat-blade screwdriver and the other end to ground. While holding the plastic part of the insulated Screwdriver, touch the support of the Anode with the tip of the Screwdriver. A cracking noise will be heard as the voltage is discharged.
GND on the CRT Location of Anode Cap
3. After one side is removed, pull in the opposite direction to remove the other. NOTE Take care not to damage the Rubber Cap. INSTALLATION 1. Clean the spot where the cap was located with a small amount of alcohol. (Refer to Fig. 2-3.)
Fig. 2-3 NOTE Confirm that there is no dirt, dust, etc. at the spot where the cap was located. 2. Arrange the wire of the Anode Cap and make sure the wire is not twisted. 3. Turn over the Rubber Cap. (Refer to Fig. 2-4.)
CRT
Support Alligator Clip
Screwdriver
GND on the CRT
Fig. 2-1 2. Flip up the sides of the Rubber Cap in the direction of the arrow and remove one side of the support. (Refer to Fig. 2-2.)
Fig. 2-4 4. Insert one end of the Anode Support into the anode button, then the other as shown in Fig. 2-5.
Rubber Cap
CRT Support
Fig. 2-2
Support CRT
Fig. 2-5 5. Confirm that the Support is securely connected. 6. Put on the Rubber Cap without moving any parts.
|
|
 |
> |
|