Who's Online
There currently are 5729 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
It was just what I need to fix my old BMW's CD player. Very convenient also. Thank you.
;
Great Manual! It contains all the wiring schematics and mechanical exploded views that are essential for service and repair. I was surprised I even found this for such an old machine. Only wish I knew of this site many years ago.
;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
;
Good pdf of the service manual for this unit. Includes disassembly instructions, full schematics, board layouts, parts lists and diagnostic information. Some information is in the pdf twice (single pages, and split pages), but that could be how it was originally generated by panasonic, or perhaps the idea is to make it eaiser to put onto 8.5 x 11" pages.
Information was exactly what I needed. Delivery was overnight (less than 12 hours) and I was happy with the process.
;
5 STARS for FAST DELIVERY, BEST PRICES and QUALITY PRODUCT. Item was exactly as described with superb resolution. Will definitely source all my future requirements from this website. Thanks a lot owner-manual.com!
MZ-NH900
3-6. Laser Power Check Procedure: 1. In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode. 2. Open the lid and press the . key continuously until the optical pick-up moves to the most inward track. 3. Set the laser power meter so that the laser beam from the optical pick-up aims at the objective lens of laser power meter at right angle. 4. Press the [VOL--] key once to display as follows.
Display
Example of Calculation:
Result Item No. 0211 0212 0213 0214 0215 0216 Parameter Pr_nominal 2.50 mW Decimal 50 30 147 40 38 116 Hexadecimal 32h 1Eh 93h 28h 26h 74h
Kr �0.3 %/°C Pw_nominal 7.35 mW Kw �0.4 %/°C Prmin 1.9 mW Pwmin 5.8 mW
9 DESIGN
Procedure: 1. In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode. 2. Press the > key once, press the [VOL+] key once, and press the > key once again to display as follows.
Display
5. Press the > key three times to select the item number 9111 and display as follows.
Display
210 DiscPr
111 ###S**
6. Confirm that the value of laser power meter is 0.67 mW ± 21%. 7. Press the > key to select the item number 9112. 8. Confirm that the value of laser power meter is 0.76 mW ± 18%. 9. Press the > key to select the item number 9113. 10. Confirm that the value of laser power meter is 6.25 mW ± 12%. 11. Press the x key four times and back to the Display Check mode. 3-7. Setting The Adjustment Values 3-7-1. Hi-MD3 setting Preparation: 1. Perform calculation every item based on the data given by the Hi-MD3 adjustment disc by referring to the following table. (Round off the value in decimal place) 2. Convert the calculated value into hexadecimal number.
Note: The Hi-MD3 adjustment parameters vary depending on the disc, and therefore use the parameters of the disc used when performing the adjustment. Item No. 0211 (*1) 0212 0213 (*2) 0214 0215 0216 Calculating formula (*3) Pr_nominal / 0.05 Por / 0.05 Kr � (�100) Pw_nominal / 0.05 Ppw / 0.05 Kw � (�100) Prmin / 0.05 Pwmin / 0.05
3. Press the > key once to select the item number 0211. 4. Adjust with [VOL+]/[VOL--] keys so that the adjustment value of LCD becomes calculated value. 5. Press the X key to write the adjusted value. 6. Press the > key to next item. 7. Repeat adjustment from step 4 until item number 0216. 3-7-2. Other setting 1. In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode. 2. Press the > key five time to select the item number 0113 and display as follows.
Display
113 ###S**
adjustment value (hexadecimal)
3. Press the [VOL+]/[VOL--] key and set the according value to each model type and destination referring to the following table. 4. Press the X key to write the adjusted value.
Destination US Canadian, Australian AEP, UK, East European E18, Hong Kong, Taiwan, Korean, Chinese, Tourist Adjustment value 41 21 A1 25
� Abbreviation E18: 100V - 240V AC area in E model Table 3-7-2. Mode Type and Destination Setting
*1) If the �Pr_nominal� value is indicated, use the �Pr_nominal� value and not used �Por� value. *2) If the �Pw_nominal� value is indicated, use the �Pw_nominal� value and not used �Ppw� value. *3) Round off after the decimal point.
Table 3-7-1. Hi-MD3 adjustment parameter