4.8.05 End of Forms Sensor Test
This test checks the operation of the end of forms sensor on the sensor board. 1. Power OFF the unit. 2. Move the two pin jumper on connector J13 of the system board to the position shown below.
3. Power ON the unit. 4. Check the sensor by performing either of the steps listed below. -- Activate the end of forms flag. -- Place a piece of paper in the manual feed slot.
5. The power light should go on and off as the flag moves past the sensor. If it does not, replace the system board. 6. Power OFF the unit to end the test. 7. Return the jumper to its original pin position after completing the test.