Superb rendition. Drawings (schematics) complete and unabridged. I do a great deal of vintage audio restoration. Documentation is essential for successful repairs. I have found sources over the years that offer good documentation, but rarely all that is necessary. Owner's Manuals has filled that void with complete and legible documentation. They have narrowed my "favorites" to a more manageable collection. This Denon manual in particular contained the latest revisions level, and offered alterations favorable to updating the item. The Illustrated Parts Breakdown (IPB) was well enough detailed to simplify part symbols and physical locations. You will not be disappointed!
 ;
Clear and concise. Saved me a lot of time and money.
 ;
Superb manual. Exactly what I ordered and made available in a very timely manner.
Page: 142
Service Guide OJ2010
Chapter 4 Failure and Repair Analysis
4.8.05 End of Forms Sensor Test
This test checks the operation of the end of forms sensor on the sensor board. 1. Power OFF the unit. 2. Move the two pin jumper on connector J13 of the system board to the position shown below.
3. Power ON the unit. 4. Check the sensor by performing either of the steps listed below. -- Activate the end of forms flag. -- Place a piece of paper in the manual feed slot.
5. The power light should go on and off as the flag moves past the sensor. If it does not, replace the system board. 6. Power OFF the unit to end the test. 7. Return the jumper to its original pin position after completing the test.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
|
|
 |
> |
|