Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The AKAI 1720 model reel to reel tape recorder described in this Manual is quite an old unit - circa late 1960's. As a consequence, the description of the mechanical details - and adjustments thereof - is quite critical. The manual does this quite well. The schematics are also well presented and have detailed PCB overlays. Probably the only negative is that some half-tone detail has been lost from the original manual as it has been scanned in simple B&W.
 ;
Perfect source for service manuals: fast and professional transaction; high quality, perfect readable and largely scaleable PDF; complete schemes, diagrams and spare part list. Tnx a lot, cu again!!!!
 ;
I got your link from a friend and I must say that I am really satisfied with your service. Specially this B&O manual I didn't find anywhere on the web... but you could deliver it :-) . You deliver very fast and the copy is of good quality. So your webpage is bookmarked. Thanks
 ;
This was the Sony CCU-500A Service manual I was looking for.
The price was reasonable.
The permission to download was quck.
I will use Owner-Manual.com for all my manual needs.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
5.
Press the UP/DOWN button to select the item CONT. Then Press UP/DOWN to adjust the waveform as Fig. 2. Then press Enter button to return. Gout
2.8+/-0.1V
Fig.2 6. Setup for oscilloscope as follows. CH1: 1V/div => TL45(Gout), CH2: 1V/div => TL44(Rout), Time: 10us/div, Trigger: TL1(VCOM), Falling Edge. Press the UP/DOWN button to select the item SBRTR. Then Press UP/DOWN to adjust the waveform as Fig. 3. Then press Enter button to return. Rout, Gout or Bout, Gout
7.
Fig.3 8. Setup for oscilloscope as follows. CH1: 1V/div => TL45(Gout), CH2: 1V/div => TL46(Bout), Time: 10us/div, Trigger: TL1(VCOM), Falling Edge. Press the UP/DOWN button to select the item SBRTB. Then Press UP/DOWN to adjust the waveform as Fig. 3. Then press Enter button to return. Setup for oscilloscope as follows. CH1: 1V/div ---, CH2: 1V/div => TL1(VCOM), Time: 10us/div, Trigger: TL1(VCOM), Falling Edge. Select the item VCOM. Then Press UP/DOWN to adjust the waveform as Fig.4. Adjust the voltage peak to the range of 5.6+/-0.1V. Then press Enter button to return. Press the UP/DOWN button to select the item DAC. Then to adjust the waveform is shown as fig. 4. The value is �1.7+/-0.1V. Then press Enter button to return. VCOM 5.6+/-0.1V -1.7+/-0.1V
9. 10.
11. 12.
Fig.4 13. 14. Press the UP/DOWN button to select the item H_POS. Then to set the green edge to center of LCD. Then press Enter button to return. Power off the camera after calibration. Remove the SD Card and AC Adapter cable.