I didn't realise a manual for an early plasma TV such as the one we were gifted could be so easily obtained. No manual was supplied with it, and as senior citizens we were a little puzzled over some aspects of its use. I do not want a listing for your store credit as we are not fairly big computer users. The manual was well organised, as it should be, with its backing of the Pioneer name. The download was prompt and everything worked quite smoothly. Thank you. Gordon.
 ;
Thank you very much for the manual. It is what I needed and it will be very helpful to me. The delivery of the manual was easy and very fast. I strongly recommend this site to other users. Best regards.
 ;
Excellent!! Got what I need and very fast!! Thank You
 ;
Manual acquired with good resolution, complete in all its pages, very good policy of the folder where are saved all products purchased.
 ;
Service manual very complete and clear. It was very helpfull for my work.
1
2
3
4
2 Actual Vofs adjustment (1)
A
(From 1 )
(Check Vofs_max1 with the red 760 signal.) Perform aging with RST MASK 01 (white) displayed for 3 seconds: MKS S51
Set to RST MASK 17 (pale purple).
MKS S67
Set VOL OFFSET to 024 (15 [V] ).
B
VOF 024
Are there any dark cells? Yes Gradually increase Vofs data VOF ��� until dark cells disappear (Vofs should be 255 (60 [V]) or less).
No
Set Vofs_min1 to 024 (15 [V]).
Note: This setting value becomes the value for Vofs_min1.
Vofs_min1
[STEP]
Note: Take note of the value for Vofs_min1.
Is Vofs_min1 144 (38 [V]) or smaller?
C
No
Replace the panel again or abnormality in circuits
Yes
Return the Vofs value to the tentative voltage setting.
VOF ���
Note: for checking the lower limit of Vofs accurately. This is
(Check Vofs_min2 with the sky color signal.) Perform aging with RST MASK 01 (white) displayed for 3 seconds: MKS S51
D
Set to RST MASK 16 (sky color).
MKS S66
Set VOL OFFSET to 024 (15 [V] ).
VOF 024
Are there any dark cells? Yes Gradually increase the Vofs data until dark cells disappear (Vofs should be 255 (60 [V]) or less).
E
No
Set Vofs_min2 to 024 (15 [V]).
VOF ���
Note: This setting value becomes the value for Vofs_min2.
Vofs_min2
[STEP]
Note: Take note of the value
Is Vofs_min2 144 (38 [V]) or smaller? Yes
No
Replace the panel again or abnormality in circuits
for Vofs_min2.
Return the Vofs value to the tentative voltage setting.
Note: This is for checking the lower limit of Vofs accurately.
F
(To 3 )
124
1 2
PDP-6071PU
3 4
|
|
 |
> |
|