Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Good-quality scans. Detailed description. I hope I can repair the machine.
 ;
High-quality scanning. Detailed description. Recommend for all technician. A+++
 ;
This is a good quality scan of the original Service Manual from Nordmende, Germany. Contains the circuit diagram, PCB layout, adjust/tune instructions as well. It is NOT in English but in GERMAN language! That was quite right for my german friend from the lower east side in Berlin.
 ;
Received via e-mail this PDF manual is worth the money. This is a quality scan of a manual in excellent condition and is just as good as having the original manual in hand. I have later seen the original manual and it was printed in colour, but this particular manual is black & white but scan resolution is high end quality! All drawings and pictures are presented in great detail. So, nearly perfect score in my opinion.
If you own the turntable you also should own the manual!
 ;
I was very satisfied with the service manual I ordered and downloaded. I will definitely buy again from this seller.
3-4. Adjust Signal Level
3-4-1. Component Level Adjustments
1. Input the Component signal to the INPUT-A. Then, from INPUT-A of the SET SETTING, select the COMPONENT (15K Component color bar chroma ON). 2. Set the COLOR to 50. 3. Connect the Oscilloscope to the TP5305 (B OUT) of the C board . 4. Enter the item OTHER of Device Adjust of the menu. 5. Set 06 3D GAMMA/ THROUGH : 0 to 06 3D GAMMA/ THROUGH : 1. 6. Set 07 3D GAMMA/ SW : 1 to 07 3D GAMMA/ SW : 0. 7. Advance the item RGB-MTRX of Device Adjust of the menu. 8. Select the item 08 YUV COL. Use the key � or �, or both, to adjust level of two color bars, the left and right end so that they will come to the same level. 9. Select 09 SUB HUE, then adjust the level of centrally adjoining two color bars in the midst of all bars, using the key � or �, or both so that they can be made flat. 10. Press ENTER key and select � SAVE TO MEMORY �. For saving the data, press the ENTER again.
both, to adjust the level of two color bars, the left and right end so that they will come to the same level. 6. Select 09 SUB HUE, then adjust the level of centrally adjoining two color bars in the midst of all bars, using the key � or �, or both so that they can be made flat. 7. Press the ENTER key and select � SAVE TO MEMORY �. 8. For saving the data, press the ENTER key again.
(1080/60i 100% Color bar) Fig. 3-4-2
3-4-3. Adjust 15K RGB Level
1. Set the COLOR to 50. 2. Connect the Oscilloscope to the TP5305 of the C board. 3. Input the Color bar signal 15K RGB 100% to the INPUT-A (5BNC). Select COMPUTOR from the INPUT-A of the SET SETTING. 4. Enter the item RGB MATRX of Device Adjust of the menu. 5. Select the item 08 YUV COL. Use the key � or �, or both, to adjust the level of two color bars, the left and right end so that they will come to the same level. 6. Select 09 SUB HUE, then adjust the level of centrally adjoining two color bars in the midst of all bars, using the key � or �, so that they can be made flat. 7. Press the ENTER key and select � SAVE TO MEMORY �. 8. For saving the data, press the ENTER key again.
Adjust GND to bottom ege in the DC 0.5 V range.
(15K Component color bar/Chroma ON) Fig. 3-4-1
3-4-2. Adjust X2 Component Level
1. Set the COLOR to 50. 2. Connect the Oscilloscope to the TP5305 of the C board. 3. Input the Color bar signal 1080/60i 100% to the INPUT-A. Select the DTV-YPbPr from the INPUT-A of the SET SETTING. 4. Enter the item RGB MATRX of Device Adjust of the menu. 5. Select the item 08 YUV COL. Use the key � or �, or 3-2
(15K RGB 100% Color bar) Fig. 3-4-3