Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
Alignment and Adjustment
b-2. Press �ENTER(CONFIRM)� button so that the white vector moves to the center on screen of the vectorscope. b-3. Store the data to mode 0A2, 0A3, 0A4 and 0A5. b-4. The OSD shows �OK!�.
7. Pre white balance (II) ; (B-Y) 1) Camera �E-E�, 3100°K gray-scale chart. 2) Video(output) jack and AF MICOM. 4) Connect vectorscope input jack to video(output) jack. 3) Press the �BLC (MODE UP)/FADE(MODE DOWN)� button so that the OSD state is �274. XX XX(High)��275. XX XX(Low)�. 5) Aim the camera at a 3100°K gray-scale chart illuminated at 1500 to 2000 lx. 6) Adjust the �P.AE(DATA UP) /DSE(DATA DOWN)� button so that the white vector moves to the B-Y axial on screen of the vectorscope. Note : Bright dot shifts after the confirm button is pressed.
Match the white luminance point with the black luminance point
Match the white luminance point with the black luminance point
Match the white luminance point with the black luminance point
8. R-Y Gain 1) Camera �E-E�, 3100°K color bar chart. 2) Video(output) jack and register of EEPROM. 3) Connect video(output) jack to waveform monitor input jack and monitor TV jack respectively. 4) Press the �BLC(MODE UP)/FADE(MODE DOWN)� button so that the OSD state is �280. XX XX(High)��281. XX XX(Low)�. 5) Aim the camera at a color bar chart illuminated at 1500 to 2000 lx. 6) Adjust the �P.AE(DATA UP)/DSE(DATA DOWN)� button so that the red level is NTSC : 70IRE, PAL : 500mV 7) Be sure to press the �ENTER(CONFIRM)� button to memorize setting. Note : Bright dot shifts after the confirm button is pressed. (outdoor : 034, 035)
6. Pre white balance (I) ; (R-Y) 1) Camera �E-E�, 3100°K gray-scale chart. 2) Video(output) jack and AF MICOM. 3) Connect vectorscope input jack to video(output) jack. 4) Press the �BLC(MODE UP)/FADE(MODE DOWN)� button so that pass through 272, 273, 274, 275 and then the OSD state is �272. XX XX(High)��273. XX XX(Low)�. 5) Aim the camera at a 3100°K gray-scale chart illuminated at 1500 to 2000 lx. 6) Adjust the � P.AE(DATA UP)/DSE(DATA DOWN)� button so that the white vector moves to the R-Y axial on screen of the vectorscope. Note : Bright dot shifts after the confirm button is pressed.
70 IRE (NTSC) 500mV (PAL)