STR-DA3ES/DA5ES/VA555ES
Ver 1.1 2002.10
SECTION 3 TEST MODE
AM CHANNEL STEP 9 KHZ/10 KHZ SELECTION MODE (DA3ES, DA5ES, VA555ES: E MODELS)
Either the 9 kHz step or 10 kHz step can be selected for the AM channel step. Procedure: 1. Set the FUNCTION to AM. Turn off the main power. 2. While depressing the [TUNING +] button press the power `/1 button to turn on the main power. 3. Either the message AM 9kHz Step or AM 10kHz Step appears. Select the desired step.
FLUORESCENT INDICATOR TUBE TEST MODE
All fluorescent segments are tested. When this test is activated, all segments turn on at the same time, then each segment turns on one after another. Procedure: 1. While depressing, the [DISPLAY] and the [ENTER] buttons simultaneously, press the power `/1 button to turn on the main power. 2. All segments turn on at the same time, then each segment turns on press the [DIMMER] button.
FACTORY SET MODE
All preset contents are reset to the default setting. Procedure: Procedure: 1. While pressing [SET UP] and [DIMMER] buttons, press `/1 button, then �TUNER FACTORY PRESET� is displayed in several seconds and PRESET is complete.
VERSION MODE
Procedure: 1. Turn power on by pressing `/1 button. 2. Press the [ENTER] and [SURROUND} buttons simultaneously, then�MENU EXPAND� is displayed. 3. Press the [>] button several times to display �@@@@ #### V.X.XX �.
ALL CLEAR MODE
Procedure: 1. Turn power off by pressing `/1 button. 2. Hold down `/1 button for 5 seconds, then �ENTER to Clear All� is displayed. 3. Press ENTER button. 4. After �MEMORY CLEARING�� is displayed for a while, �MEMORY CLEARED!� is displayed.
@ : Model name # : Destination X : Version : Sum value
SOUND FIELD CLEAR MODE
The preset sound field is cleared when this mode is activated. Use this mode before returning the product to clients upon completion of repair. Procedure: 1. While depressing the [MODE +] button, press the power `/1 button to turn on the main power. The message S.F Initialize appears and initialization is performed.
10
|
|
 |
> |
|