Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Excellent quality. Easy process to download. No issues or problems at all - was exactly what I was looking for and needed. Great service.
 ;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
 ;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
 ;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
 ;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
Adjustment > Error Messages and Countermeasure
Error Messages
TOO BRIGHT PRESS ANY KEY TOO DARK PRESS ANY KEY 1) 2) 1) 2) 3)
Countermeasure
The subject is too bright. Move the camera further away from the light box. The subject is too dark. Check the light box. Move the camera closer to the light box.
When adjusting the auto focus
AF ERROR 1) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 2) Refer to �(4) No zoom and focus operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) Check the conditions of subject. 2) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 3) Refer to �(6) No focus lens operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) Check the conditions of subject. 2) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 3) Refer to �(4) No zoom and focus operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 2) Refer to �(7) No zoom operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) Insufficient lighting. Check the subject. 1) Supply power again and readjust.
AF LIMIT OVER
TIME OUT ERROR ON AF STEP
TIME OUT ERROR ON FOCUS
TIME OUT ERROR ON ZOOM
TOO DARK TRACE ERROR. ADJUST ZOOM TRACE & AF NOISE AGAIN ERROR!! SPOT NOISE COMPENSATION IS STOPPED BY INITIAL DATA. PLEASE CHECK THE EEPROM. PRESS ANY KEY. ERROR!! THE SPOT NOISE IS TOO MANY. CAN'T COMPENSATE ANY MORE. PRESS ANY KEY. ERROR!! THRESHOLD DATA ERROR. PLEASE CHECK THE EEPROM. PRESS ANY KEY.
When adjusting the spot noise
1) Spot noise compensation is inhibited by the data in the EEPROM. 2) Turn the power on again. 3) Data in the EEPROM is defective. (data Initialize it.) 4) Check the EEPROM, and if necessary, replace it. 1) The amount of spot noise that can be compensated reaches the limit. 2) Turn the power on again. 3) Check the image sensor, and if necessary, replace it. 1) Turn the power on again. 2) Data in the EEPROM is defective. (data Initialize it.) 3) Check the EEPROM, and if necessary, replace it.