Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 DR-M4 DENON Service Manual by Dmitry Khazov;
Great quality complete service manual! complete parts list and drawings. Thanks!
 6300 NAD Service Manual by Ferhat Feradov;
Very good quality, prompt response. This website has reasonable prices and wide range of manuals that are hard to find.
 D25 SONY Service Manual by Yang Xing;
The document was usefull, and it was exactly what I was looking for.
 PCM100L/LB JVC Service Manual by Dušan Demovi?;
OK?..manual is complet and helpfull... for repairing such a old and rare boombox like JVC PCM it is necessary...
 CCU-700AP VOLUME1 SONY Service Manual by Ralf Made;
Super Anleitung. Ordentliche Auflösung. Das ganze noch in Deutsch wäre zu schön. Alle Datenblätter sind sauber Kopiert und alle Leitungswege sind sauber ausgeführt

Text excerpt from page 10 (click to view)
VL-SD20S/H/E
<REW back tension standard> (If the tension fluctuates, read its center value.) 15 ± 15 mN (1.5 ± 1.5gf )
10 1.0

VL-SD20U

6-8. Checking of winding Tu reel base ratchet torque
DC3V, without cassette controller assembly (Independent Mechanism) (1) Remove the cassette controller assembly, then apply DC3V to the loading motor and put the system into standby mode. (refer to 8-1) (2) Move the swing arm toward the S reel base side. Be careful not to prevent damage to the gears and other parts all this while. (Fig. 8) (3) Set a back tension measurement reel hub on the Tu reel base. (4) Using a dial tension gauge, pull the string in the A direction, then confirm that the tension is within the standard. <Winding Tu reel base ratchet torque standard > (If the tension fluctuates, read its center value.) 90mN or less (9gf or less )

Move the swing arm toward the S reel base side.

A

6-9. Checking of rewinding playback (VS-REW) back tension
DC3V, without cassette controller assembly (Independent Mechanism) (1) Remove the cassette controller assembly, then apply DC3V to the loading motor and put the system into rewinding playback (VS-REW) mode. (refer to 8-1) (2) Move the swing arm toward the S reel base side. Be careful not to prevent damage to the gears and other parts all this while. (3) Set a torque gauge on the Tu reel base. (4) Turning the torque gauge to counterclockwise (1 turn for 3 seconds), then confarm that the torque is within the standard. <Rewinding playback (VS-REW) back tension standard value> (If the tension fluctuates, read its center value.) 0.70 ± 0.35mN·m (7.0 ± 3.5gf·cm)

Fig. 7. Loading back tension measurement method

6-10.Checking of pinch pressing force
DC3V, without cassette controller assembly (Independent Mechanism) (1) Set the pinch roller pressing force measuring thread on the pinch lever (position A , Fig. 9). (2) Set the mechanism to the playback mode, press the pinch roller against the capstan axis. (3) Fit the tension gauge to the pinch roller pressing force measuring thread, pull in the arrow B direction shown in Fig. 11 to separate a little the pinch roller from the capstan axis. (4) Gradually return the pinch roller, and when the pinch roller contacts parallel the capstan axis, read the value (see Fig. 10) to make sure that the value conforms to the standard shown below. <Standard> 1.8 ± 0.3N (180 ± 30gf) <Caution> After making this measurement, quickly release the system from playback mode and remove the pinch roller from the capstan shaft. (If the pinch roller is left fitted onto the capstan shaft for a long time, the pinch roller will be deformed.)

Move the swing arm toward the S reel base side.

A

Fig. 8. Winding Tu reel base ratchet torque measurement method

Pinch roller

Capstan shaft

Right guide

A

B
OK NG

Fig. 9

Fig. 10

Fig. 11

6-3

You might also want to buy

$4.99

VL-SD20S SHARP
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

VL-SD20S SHARP
Parts Catalog

Parts Catalog only. It's available in PDF format. Useful, if Your equipment is broken and You need t…
>
Parse Time: 0.257 - Number of Queries: 103 - Query Time: 0.049