Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is the correct service manual of SHARP RX-100H(BK) DAT.
 ;
The ervice manual for my 1982 Kenwood KR-1000 receiver is great! Full detail on all circuits with part number detail. I will definately be ordering more manuals for my other vintage equipment! Order was fulfilled quickly! Very efficient ordering process! Thnaks for your help! Great site!
 ;
Everything in the manual was excellent except for a couple of pictures of specific areas in the unit that were a little dark. Owners Manuals re-sent the pdf file & the problem was corrected. Excellent product! George
 ;
Thanks for offering this item at such a good price. Proved handy in identifying the part I was looking for my set.
Thanks again.
 ;
This is the original manufacturers service manual, with detailed info on the circit boards, explosion drawings of all parts in assembly order, and tuning instructions. The only thing missing is the information on the dimensions of the various drive belts. mail me if you need them. gcrossman_at_aol.com
SECTION 3 ELECTRICAL ADJUSTMENTS
The set should be connected to a master unit for electrical adjustments (See page 2). Local OSC Adjustment Setting:
ANTENNA jack
oscilloscope main board TP LO
Frame Sync Adjustment Setting: ANT +B switch : ON
oscilloscope ANTENNA main board TP IF2 CH-1 set CH-2
Procedure: 1. Adjust T102 so as to maximize the peak of waveform at 35.84 MHz. Adjustment Location: See page 6. IF2 Output Gain Adjustment Setting:
digital voltmeter main board TP LEL
main board TP FSYNC
Procedure: 1. Receive the DAB signal. 2. Adjust RV104 so that the rising edge of waveform of TP FSYNC is positioned A. (1) In case of Band ��� (from channel 5A to 13F)
TP IF2
TP FSYNC
Procedure: 1. Adjust RV101 so that the reading on digital voltmeter is 2.25 V. Adjustment Location: See page 6. AGC Adjustment Setting: ANT +B switch : OFF
�1.68000 ms �680.00 us 200 us / div 5.00000 V
A
320.00 us realtime
1 500 mV/ 2 2.00 V /
�1.12500 V
(2) In case of L Band (from channel L1 to L23)
RF SSG ANTENNA jack digital main board voltmeter TP AGC 0.01 µF set
TP IF2
output level : 90 dBm (32 mV) Non-modulation
A
TP FSYNC
Procedure: 1. Set the carrier frequency of RF SSG to 225.648 MHz. 2. Receive the channel 12B (225.648 MHz). 3. Adjust RV102 so that the reading on digital voltmeter is 3.1 ± 0.5 V. 4. Set the carrier frequency of RF SSG to 1471.792 MHz. 5. Receive the channel L12 (1471.792 MHz). 6. Adjust RV103 so that the reading on digital voltmeter is 3.2 ± 0.5 V. Adjustment Location: See page 6.
�370.00 us
1 500 mV/ 2 2.00 V /
125.000 mV 3.00000 V
�120.00 us 50.0 us / div
130.00 us realtime
Adjustment Location: See page 6.